4.11 Test Images
Some thinner CameraLink
®
cables have a predefined direction. In these cables
not all twisted pairs are separately shielded to meet the RS644 standard. These
pairs are used for the transmission of the RX/TX and for the CC1 to CC4 low
frequency control signals.
Figure 4.50: LFSR test pattern received at the frame grabber and typical histogram for error-free data
transmission
Figure 4.51: LFSR test pattern received at the frame grabber and histogram containing transmission errors
CameraLink
®
cables contain wire pairs, which are twisted in such a way that the
cable impedance matches with the LVDS driver and receiver impedance. Excess
stress on the cable results in transmission errors which causes distorted images.
Therefore, please do not stretch and bend a CameraLink cable.
In robots applications, the stress that is applied to the CameraLink
®
cable is especially high due
to the fast movement of the robot arm. For such applications, special drag chain capable cables
are available. Please contact the Photonfocus Support for consulting expertise. Appropriate
CameraLink
®
cable solutions are available from Photonfocus.
MAN064 02/2020 V1.1
63 of 109
Содержание MV1-D1024E
Страница 1: ...Photonfocus MV1 D1024E Camera Series CMOS camera with Camera Link interface MAN064 02 2020 V1 1...
Страница 6: ...CONTENTS 6 of 109 MAN064 02 2020 V1 1...
Страница 10: ...1 Preface 10 of 109 MAN064 02 2020 V1 1...
Страница 14: ...2 How to get started CameraLink Figure 2 4 PFRemote start window 14 of 109 MAN064 02 2020 V1 1...
Страница 68: ...5 Precautions 68 of 109 MAN064 02 2020 V1 1...
Страница 94: ...8 Graphical User Interface GUI 94 of 109 MAN064 02 2020 V1 1...
Страница 104: ...12 References 104 of 109 MAN064 02 2020 V1 1...
Страница 108: ...A Pinouts 108 of 109 MAN064 02 2020 V1 1...