background image

Product Operation 

Usage 

The following instructions will ensure safe and 

correct use of your Photocentric Wash unit:

•  Step 1:

 

Place ultrasonic cleaner on a flat, 

stable surface.

• 

Step 2

Add Photocentric Cleaner to a level 

where it will not overflow – approximately 

2/3 full. 

•  Step  3:

 Plug in the cleaner and switch 

on via the switch at the rear of the unit if 

present, otherwise at the wall socket. (If no 

buttons are pressed, after eight hours your 

ultrasonic cleaner will go into power save 

mode. To restore power, press any button. 

•  Step 4:  

Place your printed part, platform or 

flexplate into the ultrasonic cleaner. If your 

Photocentric Cleaner is completely full 

of liquid with the printed parts immersed 

then place the lid back in your cleaner to 

prevent spillage.

•  Step  5: 

Set  the  timer  to  the  relevant 

settings; we advise a maximum of 5 

minutes for most printed parts. Once set, 

press the on button and this will enable the 

ultrasonic function.

•  Step 6: 

To end the cleaning process, press 

the corresponding key again; if nothing is 

pressed the ultrasonic will stop when the 

timer reaches 00:00 - if in use the heater 

will switch on and off to maintain the fluid 

at the target temperature.

PHOTOCENTRIC RESIN CLEANER

SKU. RESIN-CLEANER 5LTR

CLEANER

Resins

e

5060151503022

PHOTOCENTRIC RESIN CLEANER

SKU. RESIN-CLEANER 5LTR

CLEANER

Resins

e

5060151503022

WASH 15

Set ¼C

TEMP+

TEMP-

ON/OFF

ON

TIME+

TIME-

ON/OFF

Actual ¼

C

Minute

Second

Do not use w

hen empty

Minimum fill 

level 2/3

Caution hot 

liquid

Earth must b

e connected

ON

NO

05:00

05:00

5

4

Отзывы: