Bilge Pump Inputs (2)
The Bilge Pump Inputs will monitor the number of on/off cycles and
the accumulated run time of your bilge pumps. The alarm param-
eters can be programmed to detect whether the bilge pump runs too
frequently (cycle rate alarm) or for too long a period (maximum run
time alarm). To aid in determining the appropriate alarm parameters
for your boat, set the input mode to status only and monitor the
display for a day or so. It will show bilge pump activity as follows:
Bilge Pump 1
OFF
Cycle: 0
Time:0:00
Max Cycle Rate:
0
Max Runtime:
0:00
1.
The real time status, on or off, of the bilge pump.
2.
Number of cycles and accumulated run time over a 24 hour
period starting at 12 am. (This resets to 0 at 12 am)
3.
Maximum # of cycles over the programmed cycle rate alarm
period.
4.
Maximum run time of any one cycle.
To program the bilge pump alarm parameters:
Press
SET
.
Press
BILGE
#1 or
BILGE
#2.
or
The input mode will be displayed. Press the
MODE
key on the keypad
until the appropriate mode is shown on the display. The default for
bilge #1 is active. The default for bilge #2 is off. Press
ENTER
.
Press the
MODE
key to toggle through the three input modes.
Press
ENTER
.
Содержание Boat Remote
Страница 1: ...User s Manual Phonetics Inc Marine Division 901 Tryens Road Aston PA 19014...
Страница 6: ...Boat Remote User s Manual vi...
Страница 10: ...Boat Remote User s Manual x...
Страница 16: ...Boat Remote User s Manual 16...
Страница 60: ...Boat Remote User s Manual 60...
Страница 78: ...Boat Remote User s Manual 78...
Страница 82: ...Boat Remote User s Manual 82...
Страница 88: ...Boat Remote User s Manual 88...
Страница 90: ...Boat Remote User s Manual 90...