background image

5

USEPHOENIX.COM

1.800.533.7533

Specifications subject to change without notice.

5.4 GFCI Protection and the On-Board Duplex 

Outlet

The standard AC voltage outlet GFCI (Ground Fault Circuit 

Interrupter) promotes operator safety in wet applications. 

GFCI devices trip when a fault to electrical ground is sensed. 
It is recommended to check the GFCI protection prior to 

operation. To check, push the “TEST” button located on the 

GFCI duplex outlet will pop out. If operating properly the 

“RESET” button on the GFCI outlet will pop out. Depending 

on your Centrifugal Air Movers specific equipment, a tripped 

GFCI may be indicated by a small LED. The device can only 

be “RESET” when the Centrifugal Air Mover is connected to a 

wall outlet providing standard voltage. This duplex AC outlet 

allows the inter-connection of other AC powered devices. The 

sum total amperage of all devices (excluding the first fan) 

plugged into the receptacle must not exceed 8.5 amps.

6 How to Stack

Place your first fan on the floor, motor side down.  Pick up 

your second fan and orient it above the first fan.  Engage 

the alignment nubs on the side of both snouts.  Rotate the 

second fan down into position until the grills engage.  If the 

fans will be transported while stacked, they must be securely 

strapped into position.

Low Speed:

Quiet Operation

7 Maintenance

WARNING: Disconnect the unit from power before servicing 

or cleaning. Replace the safety grill after  

servicing, lubrication or cleaning. 

7.1 Servicing

Before each use, inspect for damage, blocked inlet or outlet, 

or any excess buildup of foreign material.
Inspect the GFCI to ensure it is not in a “tripped” condition. 

Push “RESET” to reset the GFCI.
When the Phoenix Centrifugal Air Mover Pro is first turned 

on, check for excessive vibration. If the unit vibrates 

excessively or if blower wheel rubs on housing, turn off the 

unit immediately. Have a service technician inspect the unit 

to locate the problem.

7.2 Cleaning

The housing is made of a durable and washable 

polyethylene. When cleaning, the use of solvents is NOT 

recommended. 

8 Replacement Parts and 

Optional Accessories

4030989               motor, 60HZ
4027572               blower wheel
4029721               rocker switch
4025458               red pilot light
4029742               cord
4030982               inlet grill, motor side
4030983               inlet grill, wheel side
4030984               grill, snout
4025203               breaker
4025205               GFCI

Contact the factory at 1-800-533-7533 to order 

replacement parts, or optional accessories

PNs 4030990 and 

4030980 are pictured 

to demonstrate 

maximum stackability.

Содержание Stackable CAM Pro

Страница 1: ...AM Pro is ETL Listed UL Certified The Phoenix Stackable CAM Pro is also lightweight and properly balanced for easy handling Other convenience features include a lighted cord for easier determination of power to the outlet and superior cord management for better handling packing and storage The Phoenix Stackable Centrifugal Air Mover Pro 2 Speed 1 3 Horsepower Motor 2 6 Amps on High Speed 2 0 Amps ...

Страница 2: ...ginally installed after servicing or cleaning the product Never place your face hands or other susceptible body parts in the air stream inlets or outlet of this device This fan is not a toy Ensure children do not play with and do not have access to the equipment Do not allow children to play with or stand near the unit or in its air flow Do not use this fan with any solid state speed control devic...

Страница 3: ...ohol or medication LIRE ET CONSERVER CES INSTRUCTIONS Risque de choc électrique Peut causer des blessures ou la mort Débrancher toutes les alimentations en courant électrique à distance avant l entretien ou le nettoyage Ne pas utiliser l appareil avec un cordon d alimentation coupé ou effiloché Ne pas débrancher l appareil en tirant sur le cordon Tenir la fiche fermement et la tirer hors de la pri...

Страница 4: ...sephoenix com sales thermastor com Toll Free 1 800 533 7533 4 Operation Instructions The Phoenix Centrifugal Air Mover is intended for use by water damage restoration carpet cleaning construction and janitorial sanitation professionals in general ventilating and structural surface drying applications The Phoenix Centrifugal Air Mover as packaged is ready to be put into service Inspect the unit com...

Страница 5: ...nouts Rotate the second fan down into position until the grills engage If the fans will be transported while stacked they must be securely strapped into position 7 Maintenance WARNING Disconnect the unit from power before servicing or cleaning Replace the safety grill after servicing lubrication or cleaning 7 1 Servicing Before each use inspect for damage blocked inlet or outlet or any excess buil...

Страница 6: ...6 USEPHOENIX COM 1 800 533 7533 PUR WHT WHT LOW HIGH M 1 2 3 4 5 HOT NEUTRAL BREAKER T H W K L B WHT BLK LOAD LINE GROUNDED GFCI DUPLEX PLUG 12 AMP CIRCUIT WHT 6 ORG 9 Wiring Diagram ...

Страница 7: ... cause beyond Therma Stor LLC s reasonable control If any Phoenix Centrifugal Air Mover part is repaired or replaced the new part shall be warranted for the balance of original warranty but all warranty periods will be extended by the period of time if any that the Phoenix Centrifugal Air Mover is out of service while awaiting covered warranty service Warranty service will be performed during norm...

Отзывы: