FRONT PANEL
2 3 4 5 6 7 8 9 10
1
MPA - Professional Power Amplifier
1. POWER switch
3,6,9. Operating signal READY/PROTECT
- signal lights up green - amplifier ready to operate
- signal lights up red - signifies that, safety switch is eliminating
Banging at time of startup
Apearance of DC
Overheating of theheatsink or transformer
2,4,5,7,8,10.. Indication directing amplifier CLIP/ SIGNAL ( CH1 - CH 6)
- signal lights up green - showing present signal of output
- signal lights up red - informs the user that the entering signal is too large
1.
2.
VOL1 - VOL6 parameters regulate the amplitude of outgoing signals
OUTPUT ( CH1, CH2, BRIDGE )
3. OUTPUT ( CH3, CH4, BRIDGE )
4. OUTPUT ( CH5, CH6, BRIDGE )
5. INPUT connector ( IN1 )
6. Operation mode switch ( STEREO, BRIDGE )
7. INPUT connector ( IN2 )
8. Source switch for CH 2
9. INPUT connector ( IN3 )
10. Source switch for CH 3
11. STEREO, BRIDGE switch
12. INPUT connector ( IN4 )
13. Source switch for CH 4
14. INPUT connector ( IN5 )
15. Source switch for CH 5
16. STEREO, BRIDGE switch
17. INPUT connector IN6
18. Source switch for CH 6
19. AC Power Line IN
REAR PANEL
1 2 3 4
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19