SAFETY TIPS

EQUIPMENT SETUP
Avoid setting up the equipment areas:
- subject to direct sunlight
- exposed to high temperatures
- exposed to moisture
- subject to high vibrations
- on an uneven surface
  Non compliance can lead to damaging the outside frame and/ or other parts-
  which could shorten the allotted time of operation.

VENTILATION
     Install the equipment in the area with proper ventilation - with a distance of at
least 10cm from the rear of the device to the wall. Remember that objects such 
as curtains should not cover the ventilation openings.

PLACING OBJECTS ON TOP OF THE AMPLIFIER 
     Do not place heavy object on top of the amplifier or on the electrical cord.
Such actions could cause the top plate to be permanently deformed or the electrical 
cord to be severed.

VOLTAGE 
     The equipment cannot be plugged into a DC socket. Make sure the parameters
of the socket are known.

ELECTRICAL CORD
     When inserting the electrical cord into the socket, hold the plug firmly and make 
sure it is propely placed into the socket. Never attempt to touch the socket with 
moist hands.
     Avoid cutting, scratching, over bending, stretching, and folding the electrical cord.
Such actions could cause a fire or electrical shock.
     When unplugging the cord do not pull the wire because an electrical shock could 
result.

FOREIGN OBJECTS
 - Do not allow objects such as needles, coins, screws, etc to accidentally fall into
   the equipment through the ventilation openings. The result could be serious 
   damage to the amplifier and electrical shock.
 - At no time should water or any other liquid to be spilled on or into the equipment
   due to the high risk of fire or shock.
 - Avoid using any aerosol sprays around the equipment.

SERVICE 
    Never try to take apart, fix or repair the equipment. If problems arise at time of operation 
(interrupted sound, signals do not light up, traces of smoke arise, etc.) Immediately turn off the 
amplifier and contact an authorized dealer. If the equipment will not be used for an extented period 
of time , unplugged the amplifier from the outlet.

MAINTENANCE
    Clean the frame, the main frame, and the regulator witch a soft moist towel, lightly covered 
with a gentle detergent. Do not use any abrasive materials or detergents. Do not use any solvent 
such as alcohol or gasoline.

Содержание MPA 6-150

Страница 1: ...MANUAL http www phoenix pa com e mail info phoenix pa com PROFESSIONAL SOUND EQUIPMENT MPA 6 150 ...

Страница 2: ...the manual will not be cover and are the sole responsiblity of the owner s time and cost For example the installation of equipment the testing maintenance especially the cleaning of the filter and interchanging the fuses All of the afore mentioned repairs can be made by the dealer at the customer s own cost Guarantee does not cover Mechanical chemical and thermal damages inflicted on the equipment...

Страница 3: ...ocket Never attempt to touch the socket with moist hands Avoid cutting scratching over bending stretching and folding the electrical cord Such actions could cause a fire or electrical shock When unplugging the cord do not pull the wire because an electrical shock could result FOREIGN OBJECTS Do not allow objects such as needles coins screws etc to accidentally fall into the equipment through the v...

Страница 4: ...ignal lights up red informs the user that the entering signal is too large 1 2 VOL1 VOL6 parameters regulate the amplitude of outgoing signals OUTPUT CH1 CH2 BRIDGE 3 OUTPUT CH3 CH4 BRIDGE 4 OUTPUT CH5 CH6 BRIDGE 5 INPUT connector IN1 6 Operation mode switch STEREO BRIDGE 7 INPUT connector IN2 8 Source switch for CH 2 9 INPUT connector IN3 10 Source switch for CH 3 11 STEREO BRIDGE switch 12 INPUT...

Страница 5: ... 1 3 2 4 1 5 2 6 STEREO STEREO IN 3 IN 4 IN 5 IN 6 SOURCE BRIDGE STEREO 1 2 IN 1 IN 2 INPUT CONNECTOR BALANCED UNBALANCED GND GND OUTPUT CONNECTOR BRIDGE CH 1 CH 2 STEREO SOURCE SWITCHES BRIDGE CH 1 CH 2 BRIDGE MPA Professional Power Amplifier ...

Страница 6: ... Six independent amplifier channels and three bridging switches provide max Configuration flexibility Separate gain controls on the back panel allow convenient level balancing of all channels It features high quality 100W RMS amplifiers per zone six independent channels bridge operation available phoenix input connector output screw terminals separate gain controlers source switch parallel operati...

Страница 7: ...8 x 420 Weght 12 3 kg Block Diagram OUTPUT STAGE OUTPUT STAGE MODE MODE VOLUME VOLUME INPUT STAGE INPUT STAGE INPUT STAGE INPUT STAGE INPUT STAGE INPUT STAGE INPUT STAGE INPUT STAGE IN 1 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 1 2 3 4 5 6 1 2 1 3 2 4 1 5 2 6 VOL 1 VOL 2 VOL 3 VOL 4 VOL 5 VOL 6 1 1 1 BRIDGE STEREO BRIDGE STEREO BRIDGE STEREO CLIP CLIP CLIP CLIP CLIP CLIP CH 1 CH 2 CH 3 CH 4 CH 5 CH 4 FAN PRO...

Отзывы: