background image

3

www.UsePhoenix.com • [email protected]

Toll-Free 1-800-533-7533

2. System Description & 
Features

2.1 Description

•  The HD308 is a fuel burning appliance, designed 

to heat fluid “on demand” and provide pumped 
circulation of the fluid for use in various portable 
hydronic applications.

•  The HD308 provides a central source of hot “heat 

transfer fluid” (HTF) for use with dependent heat 
exchangers such as:

 -

Fan coils for heating and drying of structures.

 -

Multi-circuit line heat exchange hose or tubing for 
ground thawing, concrete curing, snow melting and 
slab heating.

 -

Custom hydronic heat exchange accessories and 
applications.

•  The HD308 oil-fired is designed to burn #1 or #2 light 

diesel fuel or heating oil.

•  Pumping and combustion control are achieved with 

electrical components. The FireBird HD308 requires a 
120 volt, 20 amp, 3-wire grounding circuit.

•  The HD308 is designed for consistently-efficient 

outdoor operation.

2.2 Features

•  All exposed components are made of non-corrosive 

materials such as stainless steel, brass or aluminum.

•  The “HTF” circuit includes an open, atmospherically-

vented expansion tank, which effectively eliminates 
the system from pressure vessel classification.

•  The control system includes a sequence of status 

indicator lights which provide a quick function check 
and trouble-shooting aid for the operator.

•  The combustion chamber/heat exchanger is 

2: FireBird HD308, Burner End

1: FireBird HD308, Pump End

completely fabricated from stainless steel and is not 
susceptible to corrosion. Temperature turn-down for 
prolonged periods of operation (such as for concrete 
curing) will not harm the chamber.

•  For security and environmental protection, all valves, 

controls, burner, pump, filters, “HTF”tank filler and fuel 
tank filler are either secured behind lockable access 
doors or are self-lockable.

•  An electric “Pre-heater” ensures continued clean 

lighting and combustion of diesel/light oil, even in the 
coldest of climatic conditions.

•  Temperature gauges, pressure gauge, system status 

indicator lights, “HTF” tank level gauge and fuel tank 
level gauge are visible to the operator even when the 
system is securely locked down.

•  The CSA/UL approved burner, comes with a 

permanently installed pressure gauge to simplify 
adjustment of fuel pressure when setting up the 
burner.

•  Door handles and hose connection couplers for the 

external HTF circuit are recessed so as not to create 
“snag-points” when moving, shipping or delivering the 
unit.

3. Safety

3.1 General Safety Guidelines:
CAUTION! This is a fuel burning appliance.

•  Some surfaces will become 

EXTREMELY HOT!

•  When using the fuel oil 

the chance of FIRE or 

EXPLOSION always exists!

 Always follow safe-

operating practices and comply with local fire and fuel 
handling codes.

•  Before attempting to setup or operate this equipment, 

it is imperative that the operator reads and 
understands all the information in this manual.

•  Untrained people should not attempt to operate this 

equipment until they receive proper instruction.

•  Maintain instructional and safety labels. Replace 

damaged labels.

•  Observe all posted warnings and cautions.

•  Always wear suitable protective clothing and 

accessories such as safety glasses, leather gloves, 
certified work boots and hard hat when working with or 
operating this equipment.

•  Keep children, pets and all untrained bystanders clear 

from the heater and accessories

.

Содержание 4031010

Страница 1: ...ireBird HD308 Central Hydronic Heater Installation Operation Service Instructions Read and Save These Instructions 4201 Lien Rd Madison WI 53704 1 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 Specifications subject to change without notice TS 643 06 11 Designed and built for the rigors of the restoration industry the Phoenix FireBird HD308 is the safest most efficient flexible ...

Страница 2: ...tdown 16 6 Maintenance 16 6 1 Service Instructions Checks 16 6 2 Maintenance Frequency Chart 20 7 Troubleshooting 20 7 1 Fault Determination 20 7 2 Burner Internal Faults 22 7 3 Electrical Schematics 23 Warranty 26 Serial No __________________________________ Purchase Date ______________________________ Dealer s Name ______________________________ Page 1 Specifications Part No 4031010 Fuel Input 3...

Страница 3: ...for concrete curing will not harm the chamber For security and environmental protection all valves controls burner pump filters HTF tank filler and fuel tank filler are either secured behind lockable access doors or are self lockable An electric Pre heater ensures continued clean lighting and combustion of diesel light oil even in the coldest of climatic conditions Temperature gauges pressure gaug...

Страница 4: ...llimeters 72 1829 Width of Cabinet inches millimeters 22 559 Width of Fuel Tank inches millimeters 31 787 Height of Cabinet inches millimeters 48 1219 Height of Top of Rain Cap inches millimeters 58 1473 Heat Transfer Fluid Capacity US gallons liters 20 76 Fuel Tank Capacity US gallons liters 116 439 Weight without Fuel Tank pounds kilograms 600 272 Weight with Fuel Tank Empty pounds kilograms 800...

Страница 5: ...he following scenarios is proven 1 120 volt control power is present clear lens 2 HTF level is adequate in reservoir green lens 3 Flow switch has proven adequate flow of HTF in the system green lens 4 High limit control has not interrupted the circuit green lens 5 High pressure switch has not interrupted the circuit green lens 6 Aquastat is calling for heat green lens Burner Specifications Operati...

Страница 6: ...ils of these components Main power male inlet plug twist lock Fig 7 Low water cut off switch mounted on HTF reservoir Fig 21 Flow switch mounted in HTF plumbing circuit Fig 22 High limit switch mounted in HTF plumbing circuit Fig 23 High pressure switch Fig 24 Diesel fuel pre heater Fig 5 HTF circulating pump Fig 6 see pump chart above for details Burner Fig 3 see burner chart above for details 3 ...

Страница 7: ...ting Quick couplers ensure that the connections are fully engaged and snapped into place or flow will not take place through the coupler connection For longer term building heating projects it is advised to insulate all hose sections located outdoors between the FireBird HD308 and the exterior building wall Special insulating wraps are available for this purpose Mounted Remotely on Plumbing Circui...

Страница 8: ...ace all fancoils in the desired locations and route all the hoses to them OR lay out all hose grid circuits for ground thaw or concrete curing Connect hoses from the manifold to ONE fancoil ONLY Open 2 HTF circuit valves Fig 33 Turn ON the circulating pump switch Fig 12 and let the fluid circulate until all the air is eliminated from the first branch circuit Air has been purged when steady pressur...

Страница 9: ... The high pressure switch light will turn on This indicates that the blocked flue high pressure safety switch has not broken the circuit A few seconds later the stat light will come on and the burner fan will purge the combustion chamber for a few seconds The burner should light following the pre purge If air is still present in the fuel lines the burner may not light and lock out It might be nece...

Страница 10: ... operating mode turn OFF the burner circuit power switch remove the tape cover from the burner s primary control box re insert the control and turn ON the burner circuit power switch C Examine the flue gas exhaust pipe and rain cap to be sure they are solidly attached and free from any type of obstruction Clean if necessary a This check should be performed every time when putting the system into o...

Страница 11: ...ct surfaces are now exposed and can be easily cleaned with vacuum cleaner brushes or other cleaning utensils i To re assemble the unit replace components in reverse order to which they were removed j Reconnect fuel and power supply to the unit and when re starting the system perform all safety and service checks as outlined above H The FireBird HD308 will produce condensate while operating at any ...

Страница 12: ...r switch Check the following a Is main power switch Fig 11 still turned on b Are the circuit breakers Fig 16 still turned on c Verify external power supply 120V to inlet plug Fig 7 1 Unit Power Light is ON indicates A Power is present through main switch The 2 digital temperature gauges should be ON If not use a multi meter to check the following a The 2 transformers Fig 18 should show 120VAC in a...

Страница 13: ...luid temperature has not reached the high temperature limit setpoint and power is going through the switch B There is no power going through the NC contacts of the high pressure switch Fig 24 Blockage may have occurred in the flue gas passage way a Check the chimney pipe and rain cap for blockage b Check the air tube connection to the pressure switch and clean if necessary c Clean the flue gas pas...

Страница 14: ...the fuel lines c The fuel filter is dirty Replace filter d Nozzle is plugged Replace nozzle e The spark is irregular or not present Re align electrodes C The burner does not start when the thermostat calls for heat a Loose wire connection at terminals L or N b Terminals on the control module are bent or loose c The motor is defective d The capacitor is defective e The control box is defective 7 3 ...

Страница 15: ...15 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 ...

Страница 16: ...16 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 Burner Wiring Line Voltage Sub base Wiring ...

Страница 17: ...ump Pressure Gauge 4030305 7 Fuel Pressure Gauge 4030304 8 Burner Nozzle 4030551 9 Burner Assembly 4030272 10 Igniter 4030302 5 Options and Accessories 4029790 Phoenix TX 80 Fan Coil 4030700 Manifold Kit 2 ea 4030153 3 4 x 50 Hose 4030417 3 4 x 25 Hose 4030418 3 4 x 15 Hose 4030154 1 x 50 Hose 4029876 Ductable Filter Box Kit 4021799 16 x 16 x 2 Merv 8 Filter 4028363 16 x 25 Heavy Duty Flex Duct 40...

Страница 18: ... or installation accident acts of nature or any other cause beyond Therma Stor LLC reasonable control Limitations and Exclusions If any Phoenix FireBird HD308 part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable thereto but all warranty periods will be extended by the period of time if any that the Phoenix FireBird HD308 Des...

Отзывы: