1 Safety Information

•  Do not operate the unit with a cut or frayed power cord. 

Replace cord if it becomes damaged.

•  Do not unplug the unit by pulling on the cord. Grasp the 

plug firmly and pull it out of the wall socket or power 

receptacle.

•  Always use a grounded outlet.
•  Never operate electrical equipment in standing water.
•  Never operate with the safety grills removed. Personal 

injury may result.

•  Do not stick your fingers or other objects through the 

safety grills.

•  Do not restrict airflow to the unit. This may cause the unit 

to overheat.

•  Unit should never be serviced or cleaned while it is 

plugged in.

•  Do not sit or stand on the unit or use as a shelf or table.
•  Before leaving an 50Hz Axial Air Mover unattended, 

ensure children do not have access to the equipment. Do 

not allow children to play with or near the unit or in its air 

flow.

•  To reduce the risk of fire or electric shock, do not use this 

air mover with any solid-state speed control device.

•  Do not route cord under furniture or appliances.

LIRE ET CONSERVER CES INSTRUCTIONS

•  Risque de choc électrique Peut causer des blessures ou 

la mort. Débrancher toutes les alimentations en courant 

électrique à distance avant l’entretien ou le nettoyage.

•  Ne pas utiliser l’appareil avec un cordon d’alimentation 

coupé ou effiloché.

•  Ne pas débrancher l’appareil en tirant sur le cordon. Tenir 

la fiche fermement et la tirer hors de la prise murale ou la 

prise d’alimentation électrique.

•  Toujours utiliser une prise mise à la terre.
•  Ne jamais utiliser l’équipement électrique dans de l’eau 

stagnante.

•  Ne jamais utiliser sans les grilles de protection. Des 

blessures risquent d’en résulter.

•  Ne pas passer les doigts ou d’autres objets dans les 

grilles de protection.

•  Ne pas diminuer le débit d’air arrivant jusqu’à l’appareil. 

L’appareil risque de trop chauffer.

•  Ne pas s’asseoir ou se tenir debout sur l’appareil; ne pas 

l’utiliser comme étagère ou table.

•  Avant de laisser un appareil aéraulique 50Hz Axial sans 

surveillance, s’assurer que les enfants n’ont pas accès 

à l’équipement. Ne pas laisser les enfants jouer avec 

l’appareil ou à proximité de l’appareil ou dans l’air qu’il 

projette.

•  Pour réduire le risque d’incendie ou de choc électrique, ne 

pas utiliser ce ventilateur avec un dispositif de commande 

de vitesse à semi-conducteurs.

Table of Contents

Introduction

  ............................................................................1

FOCUS

TM

 Technology Features and Benefits

.........................1

1.  Safety Information

 ..........................................................2

2.  Intended Application

 .......................................................3

3.  Safety Certifications

 ........................................................3

4.  Specifications

 ..................................................................3

5.  Power Requirements

.......................................................3

 

5.1  International Cord/Plug Set .....................................3

 

5.2 Integrated Cord Wrap ................................................3

6. Applications

 .....................................................................3

 

6.1 Sizing for Water Restoration Jobs .............................3

 

6.2 Placement ..................................................................3

 

6.3  Orienting of Directional Drying System ....................4

7.  Operating Instructions

 ....................................................4

8.  Operator Panel Features

 .................................................5

 

8.1 Run-Time Hour Meter ................................................5

 

8.2 Power Indication Lamp .............................................5 

8.3 3-Position Drying Selector Switch ............................5

9. Maintenance

 ....................................................................5 

9.1 Servicing ....................................................................5

 

9.2 Cleaning .....................................................................5

10.  Replacement Parts and Optional Accessories

 .............6

11. Wiring Diagram

 ...............................................................6

 Warranty

 ...........................................................................7

Serial No. ___________________________

Purchase Date ______/______/_____

Dealer’s Name ___________________________________

Содержание 4030940

Страница 1: ...ure designed to fit existing vehicle rigging superior cord management and hour meter Conventional 50Hz Axial air movers create a circular air jet With a circular air jet the only way to get air into the square corner is to point the fan towards the corner This angle toward the wall wastes valuable air velocity and throw distance FOCUSTM Technology creates an air jet with a square corner resulting ...

Страница 2: ...se murale ou la prise d alimentation électrique Toujours utiliser une prise mise à la terre Ne jamais utiliser l équipement électrique dans de l eau stagnante Ne jamais utiliser sans les grilles de protection Des blessures risquent d en résulter Ne pas passer les doigts ou d autres objets dans les grilles de protection Ne pas diminuer le débit d air arrivant jusqu à l appareil L appareil risque de...

Страница 3: ...ropriate grounded earthed outlet 5 2 Integrated Cord Wrap The Phoenix 50Hz Axial Air Mover features integrated cord management Wrap the cord around the cord wrap as shown and tuck under the previous wrap 6 Applications 6 1 Sizing for Water Restoration Jobs Current industry standards call for one air mover per 3 5 meters 10 16 linear feet of wall space dependent upon the Class of water damage For c...

Страница 4: ...r ships with rubber feet on one side of the unit for counter clockwise drying When the water restoration professional needs to employ clockwise drying such as the need to dry a door jamb simply rotate the 50Hz Axial air mover 90 so the FOCUS Technology corner points toward the door jamb and floor for the clockwise drying If the water restoration professional dries in the clockwise direction often ...

Страница 5: ...position drying selector switch in the OFF position or the connected standard AC wall outlet power has been turned off 8 3 3 Position Drying Selector Switch The 3 position drying mode selector switch This switch is used to select the Phoenix 50Hz Axial Air Mover s mode of operation The 3 modes of operation are OFF LOW or HIGH 9 Maintenance WARNING Disconnect the unit from power before servicing or...

Страница 6: ...ED PLUG M CAPACITOR BLK BLK left hand pole right hand pole GRY 230 VAC 50 hz Note Switch is Double Pole Double Throw GRY YEL 10 Replacement Parts and Optional Accessories Contact the factory at 1 800 533 7533 or 1 608 237 8400 to order replacement parts or optional accessories 4029721 Switch Rocker On Off On 4025320 Grill Safety Intake 4025321 Grill Safety Exhaust 4025460 Axial Air Mover Stand 402...

Страница 7: ...on freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any Phoenix 50Hz Axial Air Mover part is repaired or replaced the new part shall be warranted for the balance of original warranty but all warranty periods will be extended by the period of time if any that the Phoenix 50Hz Axi...

Отзывы: