POWER PACK 1300
13/18
76264(e)
5.2
Operation
Type of check /
action
Explanation
Time interval
Recharging
To maintain battery performance
No longer than six months
after date of manufacture.
Recharging dur-
ing storage
Recharge during storage to maintain
battery performance capability approx.
three months
At least every six months.
Limit the storage
time
Dispose of the battery after the maxi-
mum storage time is exceeded!
Maximum storage time is
12 months
5.3
Technical Data for storing the batteries
Storage temperature:
from 0°C to +40°C
Relative humidity:
from 30% to 90%
Air pressure:
from 800 hPa to 1060 hPa
Altitude
< 2000m