Phoenix Mecano Dewert Okin HE200 Скачать руководство пользователя страница 18

Troubleshooting 

CONTROL UNIT HE200 

18 

82687(-) 

8.  Troubleshooting

This chapter describes troubleshooting methods for fixing problems. If you experience an error that 

is not listed in this table, please contact your supplier. 

  Only qualified specialists who have received electrician training should carry out troubleshooting 

and repairs. 

 

Problem 

Possible cause 

Solution 

The drive, accessory 

or massage motor is 

not functioning. 

There is no mains supply voltage. 

Connect the mains power. 

The massage motor or accessory is 

defective. 

Please contact your supplier or 

sales agent. 

The hand-held remote control has 

not been programmed with the 

teach-in. 

Carry out the teach-in routine for 

the hand-held remote. 

The hand-held remote batteries are 

empty. 

Replace the batteries. 

The drive or massage 

motors are suddenly 

not capable of 

movement. 

The system protective circuit 

breaker has triggered. 

Allow the system to rest for 20 to 

30 minutes with the mains power 

unplugged. 
If this does not resolve the prob-

lem, contact your supplier or dis-

tributor. 

The unit's fuse may have been trig-

gered. 

Please contact your supplier or 

sales agent. 

The hand-held remote batteries are 

empty. 

Replace the batteries. 

Radio interference 

Try to re-establish the wireless 

connection. 

There is no mains supply voltage. 

Connect the mains power. 

A cable has been disconnected (to 

the mains power, massage motors, 

drives or accessory). 

Check the cables and reinsert 

them, if required. 

Содержание Dewert Okin HE200

Страница 1: ...CONTROL UNIT HE200 Installation Instructions Translation of the original installation instructions...

Страница 2: ......

Страница 3: ...ufacturer They should not be given to the operator of the end product The factual information contained within may be used as a basis when creating the end product manual The warning and danger notice...

Страница 4: ...and intended usage 6 2 2 Selection and qualification of personnel 7 2 3 Ratings plate 8 3 Possible combinations 9 4 Description 10 4 1 Components 10 5 Technical specifications 11 6 Installation 13 6 1...

Страница 5: ...ocedures will help to minimize the risk of accident and injury and damage to the CONTROL UNIT HE200 or the end product These installation instructions have been written with due care and attention How...

Страница 6: ...end product The CONTROL UNIT HE200 should not be used in any environment where combustible or explosive gases or vapours e g anaesthesiology may be present in the proximity of open fires or other heat...

Страница 7: ...erformed by quali fied personnel 2 2 1 Electrical safety CAUTION Electric shock Be careful there is a risk of electrical shock Before installing make sure that you disconnect the external DewertOkin p...

Страница 8: ...Ratings plate for the CONTROL UNIT HE200 example HE200 Model name xxxxx Article number 29V Input voltage 6 00A Permitted power consumption Intermittent Operation 2min 18min Mode of operation Prod dat...

Страница 9: ...at have been approved by DewertOkin A tailored system consists of the combination of control unit single drive massage motor accesso ries and hand held remote DewertOkin has separate system instructio...

Страница 10: ...ilt in radio receiver 4 1 Components The housing of the CONTROL UNIT 258 4 has a connection for an external DewertOkin drive system as well as connections for massage motors and various accessories Fi...

Страница 11: ...IP20 Dimensions and weight Length x width x height 182 mm x 101 mm x 50 mm Weight Approx 400 g Ambient conditions for operation storage and transport Transport storage temperature From 20 C to 50 C Fr...

Страница 12: ...Technical specifications CONTROL UNIT HE200 12 82687 Figure 3 Dimensions of the CONTROL UNIT HE200 top view in mm Figure 4 Dimensions of the CONTROL UNIT HE200 side view in mm 50 101 140 182...

Страница 13: ...components can be ensured by using the proper construction methods as described below 6 2 Installation procedure Before installing and connecting the CONTROL UNIT HE200 make sure that you are observin...

Страница 14: ...shown in Figure 5 located on the control unit Use screws meeting the requirements of DIN 7049 with 4 8 mm diameter and of suitable length 5 mm plus the screw in depth into the end product Proceed with...

Страница 15: ...t on the cables and the cables cannot be damaged in any way Fasten all cables especially the connecting cables to the end product using sufficient kink preven tion methods Be sure that the design of t...

Страница 16: ...verified to work when com bined together Delayed start up After plugging the power plug into the power outlet There is a delay after the supply voltage is applied before the device actually turns on...

Страница 17: ...the massage motors The power plug must always be accessible during operations so that it is possible to shut down the CONTROL UNIT HE200 Avoiding cable damage Be sure that your operating instructions...

Страница 18: ...mmed with the teach in Carry out the teach in routine for the hand held remote The hand held remote batteries are empty Replace the batteries The drive or massage motors are suddenly not capable of mo...

Страница 19: ...0 as needed using a dry cloth NOTICE Always disconnect the mains power plug from the DewertOkin external power supply before you start to clean it Never clean the CONTROL UNIT HE200 in an automated wa...

Страница 20: ...8 98 EC Waste Framework Directive WFD as of 12 12 2008 10 2 Components in the control unit The CONTROL UNIT HE200 consists of electronic components cables and metal and plastic parts You should observ...

Страница 21: ...Low Voltage Directive 2014 35 EU DELEGIERTE RICHTLINIE EU 2015 863 DER KOMMISSION vom 31 M rz 2015 zur nderung von Anhang II der Richtlinie 2011 65 EU des Euro p ischen Parlaments und des Rates hinsic...

Страница 22: ...htlinie 2011 65 EU des Euro p ischen Parlaments und des Rates hinsichtlich der Liste der Stoffe die Beschr nkungen unterliegen COMMISSION DELEGATED DIRECTIVE EU 2015 863 of 31 March 2015 amending Anne...

Страница 23: ...DewertOkin GmbH Weststrasse 1 Kirchlengern 32278 Germany Tel 49 0 5223 979 0 Fax 49 0 522375182 http www dewertokin de Info dewertokin de ID No 82687...

Отзывы: