Install float valve and hose adapter

Attach the float valve to the cabinet as shown below. The garden
hose adapter attaches to the brass inlet fitting on the float valve. 

NOTE:

 verify that the hose washers are correctly in place. 

Water connection and float adjustment

Move cooler to desired location (this should be a level area for proper 
operation of the cooler).
1. Locate a knock-out in the bottom of any of the four corner posts.
2. Connect to water supply using a commercial grade of water hose

(not supplied with cooler, obtained separately) to the adapter on
the float valve and turn water on. CAUTION: water inlet pressure
should be limited to a maximum of 65 PSI to avoid rupturing the
water hose. If pressure exceeds this value, an inline pressure
regulator should be installed (obtainable from a local plumbing or
hardware store).

3. Check that all connections are tight by visually inspecting hose,

float valve, etc. for leakage.

4. Set float valve for a water depth of 2-1/2". The float is adjusted by

lightly bending the float rod.

Your evaporative air cooler was thoroughly tested and inspected 
before leaving the factory. This is your guide to economical, trouble 
free comfort cooling over the years with reasonable care and regular 
maintenance. Failure to follow these instructions may damage your 
cooler, impair its operation and/or void the warranty

Read it carefully.

SET UP FOR ROLL-AROUND USE

• Open parts box & remove casters from parts bag. Assemble each

caster (Fig.1) per caster plate using supplied 1/4-20 nuts & carriage
bolts.

• Place casters w/ brakes on the front of the unit, and the casters

without the brakes should be mounted on the back of the cooler.
Use 4 of the 1/4-20 bolts from the parts bag to secure all 4 of the
casters to their respective caster plates. Apply brakes before lifting
cooler upright to complete assembly.

2  Master Blaster Use and Care Manual

PREPARATION FOR ASSEMBLY

Remove the pad frames by slightly lifting the pad frame from the 
bottom, pull outwards until clear of cabinet bottom pan, then 
downwards until frame clears cabinet top. Remove the following 
items from the cooler:
1. Box containing swivel casters and attachment hardware.
2. Plastic bag containing small parts, float valve, garden hose adapter,
hose nut, hose washer, o-ring.
3. Bag with hose adapter for float valve (roll-around use)

Gather tools required to assemble & install unit

The following tools are required to assemble the unit:
7/16" box or open end wrench
3/8" box or open end wrench

6" crescent wrench
1/4" nut driver

Figure 1

Install Overflow Standpipe / Drain Line

Install overflow drain bushing in bottom of cooler as follows:

• Slide rubber washer over the brass drain

bushing.

• Push drain bushing through bottom of

cooler, assemble and tighten lock nut.

• Screw plastic overflow standpipe into the

drain bushing and tighten snugly (hand 
tight) to prevent leakage.

• Where conditions allow for drainage,

connect a drain line (garden hose) to
drain bushing.

Cooler checkout and first time start-up

Congratulations, once you re-install the pad frames, your roll-around 
Master Blaster cooler will be complete and ready for use. Please 
proceed to the Pre-startup inspection checklist on page 3 before 
starting unit for the first time.

Motor and blower wheel check

Check motor mounting to be sure all screws and nuts are tightened 
down properly. Rotate blower wheel by hand to see that it moves 
freely without rubbing against housing.

Belt Tension Adjustment

   CAUTION:

Disconnect all electrical power to the cooler and insure that belt 
is not rotating before adjusting belt tension.

Correct belt tension and alignment is important, proper setup reduces 
power consumption and prolongs life of belt and motor. Check belt 
tension by squeezing belt. Proper tension will allow deflection of ½ 
to ¾ inch. To increase or decrease belt tension, loosen bolt in slot of 
motor support bracket. Adjust belt to proper tension and retighten 
bolt.

   CAUTION:

Never operate unit with pad frame(s) 
and/or air outlet grille removed. This 
will result in an overloaded condition 
and may damage the motor.

Содержание MASTER BLASTER MB10

Страница 1: ...this blower fan motor with any solid state speed control device Do NOT operate this unit with pad frame s and or air outlet grille removed this may cause the fan motor to overload and damage the moto...

Страница 2: ...es by slightly lifting the pad frame from the bottom pull outwards until clear of cabinet bottom pan then downwards until frame clears cabinet top Remove the following items from the cooler 1 Box cont...

Страница 3: ...can restart automatically when they cool down To verify and check out the cooler installation on initial start up the following procedure should be followed Push COOL switch to ON position pump on Ve...

Страница 4: ...elt tension on motor blower assembly Check belt condition and replace it if trays or cracks appear Check alignment of blower pulley with motor pulley 4 Master Blaster Use and Care Manual Cleaning Wate...

Страница 5: ...bristle brush don t use a wire brush will not harm the pad and will remove stubborn scaling 4 If necessary replace with new rigid media pads Aspen expanded paper or other types of evap cooling pads wi...

Страница 6: ...e or too tight Adjust belt tension Defective motor Replace motor Defective switch Replace switch Broken belt Replace belt Inadequate air delivery Insufficient air exhaust Open windows to increase air...

Страница 7: ...006 0001 05 006 0001 9 BUSHING NUT with BRASS HOSE CAP 05 006 0242 05 006 0242 10 WATER DISTRIBUTOR ASSEMBLY 05 006 0263 05 006 0265 11 PUMP 05 006 0034 05 006 0034 12 BLEED OFF TEE HOSE 05 006 0003...

Страница 8: ...other rights which vary from state to state Garantia Limitada Enfriador Evaporativo Phoenix Manufacturing Inc Phoenix Arizona extiende esta garant a limitada al comprador original de este enfriador e...