background image

Scope

This chapter describes the overall features and specifications of the VF2-350-SCW-RHD. 

Features

The VF2-350-SCW-RHD incorporates one very compact removable winchester disk drive within a single module.  The
hard disk drive is a high-performance winchester type with embedded disk drive control electronics.  This microproces-
sor controlled embedded controller is on the hard disk  and is compatible with ANSI X3.131-1986 SCSI commands.
The hard drive is a very high performer, with a 1-to-1 interleave and an average track-to-track access times of less than
10 milliseconds.  It incorporates an embedded cache buffer which is operated in “look ahead” mode, providing buffering
for sequential sector operations.  The hard drive has been carefully packaged with suitable control and power distribu-
tion connectors for direct attachment to single board computers in the VME chassis or to external devices.

WIDE SCSI Interface Description

In order to provide a method of embedding the disk drive control electronics within the hard disk drive, several disk
drive manufacturers jointly defined an interface specification.  This specification for the Small Computer System Inter-
face  
has become known throughout the industry as “SCSI”.  Basically, the SCSI interface consists of the required
address, data and control signals from a wide SCSI Host Adapter.  Since a goal of the specification is to allow the disk
drive to be connected via standard cable, the specification required buffering of all signals so that the drive could be
mounted a suitable distance from the board interface.  This distance, however, is limited to eighteen feet.  The specifi-
cation provides all signals via a 68-pin header connector for use with standard 68 conductor cable and connectors.
Table 2-2 is a description of the wide SCSI-2 pin definition.  The direction indicated is relative to the host.

Pin

Signal

Direction

Description

35

-DB (12)

In/Out

Bidirectional data line 12

36

-DB (13)

In/Out

Bidirectional data line 13

37

-DB (14)

In/Out

Bidirectional data line 14

38

-DB (15)

In/Out

Bidirectional data line 15

39

-DB (P1)

In/Out

Bidirectional data line Parity1

40

-DB (0)

In/Out

Bidirectional data line 0

41

-DB (1)

In/Out 

Bidirectional data line 1

42

-DB (2)

In/Out

Bidirectional data line 2

43

-DB (3)

In/Out

Bidirectional data line 3

44

-DB (4)

In/Out

Bidirectional data line 4

45

-DB (5)

In/Out

Bidirectional data line 5

46

-DB (6)

In/Out

Bidirectional data line 6

47

-DB (7)

In/Out

Bidirectional data line 7

48

-DB (P)

In/Out

Bidirectional data line Parity

49

GND

-

Ground reference

50

GND

-

Ground reference

51

TERMPWR

-

Terminator Power

52

TERMPWR

-

Terminator Power

53

RESERVED

-

Reserved for future use

54

GND

-

Ground reference

55

-ATN

In/Out

Attention

56

GND

-

Ground reference

57

-BSY

In/Out

Busy

58

-ACK

-

In

Acknowledge

59

-RST

In

Reset

60

-MSG

Out

Message

61

-SEL

In/Out

Select

62

-C/D

Out

Control/Data

63

-REQ

Out

Request

64

-I/O

Out

Input/Output

65

-DB (8)

In/Out

Bidirectional data line 8

66

-DB (9)

In/Out

Bidirectional data line 9

67

-DB (10 )

In/Out

Bidirectional data line 10

68

-DB (11)

In/Out

Bidirectional data line 11

Table 2-2: SCSI Pin Definition

NOTES:
(1) 

All pins 1-34 shall be connected to ground, except for pins 16=DIFFSENS, 17, 18=Termpwr, 19=Reserved

(2) 

The minus sign next to the signals indicates active low.

Features and Specifications

2-3

Содержание VF2-350-SCW-RHD

Страница 1: ...VF2 350 SCW RHD MASS STORAGE SUBSYSTEM Technical Information Copyright Phoenix International 1999 All Rights Reserved 812 W Southern Avenue Orange CA 92865...

Страница 2: ...nt with the product that it describes However no responsibility is assumed for inaccuracies Nor does Phoenix International assume any liability arising out of the application or use of any product or...

Страница 3: ...on 3 3 VMEbus Slot Requirements 3 3 VMEbus Backplane Requirements 3 3 Power Supply Requirements 3 3 Installing the VF2 350 SCW RHD 3 3 Drive Software Configuration 3 4 Hard Drive Software Configuratio...

Страница 4: ...aining an RMA 5 3 Shipping the Product 5 3 Providing a Product Defect Report 5 4 Warranty Repairs 5 4 Non warranty Repairs 5 4 Product Updates 5 4 Tables Table 2 2 SCSI Pin Definition 2 3 Table 2 3 P2...

Страница 5: ...Chapter 1 Manual Organization and Introduction...

Страница 6: ...This page intentionally left blank...

Страница 7: ...you have trouble and how we will support you VF2 350 SCW RHD Introduction The VF2 350 SCW RHD has been designed to provide a complete disk drive subsystem which is mechanically compati ble with the VM...

Страница 8: ...S C S I 2 1 3 0 4 7 6 6 UNIT ID I Figure 1 1 VX2 350 SCW RHD Front Panel VX2 350 SCW RHD User s Manual 1 4...

Страница 9: ...BRD C HOST TERMPWR Figure 1 2 VX2 350 SCW RHD Jumper Configuration Manual Organization and Introduction 1 5...

Страница 10: ...Chapter 2 Features and Specifications...

Страница 11: ...This page intentionally left blank...

Страница 12: ...able distance from the board interface This distance however is limited to eighteen feet The specifi cation provides all signals via a 68 pin header connector for use with standard 68 conductor cable...

Страница 13: ...y ordered See Chapter 4 for drive details Hardware Compatibility VMEbus Double Eurocard 6Ux8HP Electrical Power 5VDC 0 130A max in addition to drive current See Chapter 4 12VDC Depends on drive type S...

Страница 14: ...DB 4 A5 DB 5 A6 DB 6 A7 DB 7 A8 DPAR A9 LTERMPOWER A13 ATN A16 BSY A18 SACK A19 RST A20 MSG A21 SEL A22 C D A23 REQ A24 I O A25 GROUND A10 A11 A12 A14 A15 A17 A32 P2NONL A32 GROUND B2 B12 B22 B31 DB8...

Страница 15: ...Chapter 3 Configuration Installation and Operation...

Страница 16: ...This page intentionally left blank...

Страница 17: ...s Backplane Configuration The VMEbus P1 connector supplies all operating power to the VF2 350 SCW RHD and shunts the daisy chain signals on the P1 connector However no other VME signals are connected...

Страница 18: ...onnector on the front panel and sets the termination at the correct end of the SCSI bus If the module is in the middle of a SCSI bus route the SensiTermTM circuitry automatically disables all on board...

Страница 19: ...Chapter 5 Product Support Service and Warranty...

Страница 20: ...This page intentionally left blank...

Страница 21: ...0 and ask for Customer Service Please be prepared to supply as much detail as you can concerning the nature of the problem and the conditions in which the problem appeared Obtaining an RMA In order to...

Страница 22: ...eight prepaid to the Customer Non warranty Repairs If a product is found not to be under warranty we will notify you of the non warranty situation and provide you with a fixed cost and a schedule for...

Отзывы: