ENVIRO 6 SLIDING GATE OPERATOR
7
Fig.8
Wiring notes of control board
a. Power Input(X1):E (Earth),L (Live),N (Neutral).
ENVIRO 6: AC220V
b. Caution light: connect caution light wire toD1 and D2(terminal X3)
ENVIRO 6: AC220V
c. Output power supply: 24VDC, COM (COM), I.R. (N.C Infrared)
If the infrared beam is interrupted during closing, the gate will reverse and open immediately. The product
is not factory equipped with an infrared device, the infrared output signal must be N.C.
GND
24VDC
Out
I.R
COM
24VDC
Terminal X2
Infrared
Control board
Infrared with DC input
Signal