background image

PHOENIX CONTACT page 6  of  9

Uninterruptible Power Supply Unit for Universal Use – QUINT-DC-UPS/24DC/40

QUINT-DC-UPS

Power

Supply

+

AC

DC

Unbuffered

Load

+

DC

Buffered

Load

Input Output Battery

+

+ –

+ –

+ –

QUINT-BAT/24DC

+ –

+     

 –

D

C

 24 

V   40 

A

Inp

ut       O

utpu

t

3  14

DC

OK

+  +  

13  14

DC

OK

+  +

13  14

DC

OK

+  + 

+     

 –

+24V 0,2A

11

   21

12   13  2

11
Alarm

Bat.-Mode
Bat.-Charge

QUINT

-DC-UPS/24DC/40

Order-No.: 28 66 24 2
Input:
Operational V

oltage:

Output:

24VDC/43A
22.5-30VDC
24VDC/40A

APPROV

ALS

Read installation instructions
before connecting

- 25 … + 

  

70 

°

C

- 13 … + 158 

°

F

EN 61000-6-2
EN 50081-1

www

.interface.phoenixcontact.com

U

INDUSTRIAL
CONTROL
EQUIPMENT
43KA

LISTED

–25

F

Alarm

Power In OK

QUINT DC-UPS 40 

A

Bat.-Mode

Bat.-Charge

Batter

y

3   1

4 DC

OK

+  +  –

Alarm

Power In

OK

+      –

31  R1  R2

2  23  32  33

21
 Bat.-
Mode

31
 Bat.-
Charge

R1     R2
Remote

OFF

ON

10

15

5

3

2

1

0,5

20

30

t

max

[min]

Service

3,4

12

7,2

Bat.-Select

[Ah]

Figure 09

5.4. Connection 

The following cable cross sections can be connected: 

 For reliable and safe-to-touch 

connections:

 Strip 10 mm (0.39 in.) 

from the input and output side 
connector ends and 7 mm (0.28 in.) 
from the signal connector ends.

 To maintain UL approvals, use copper cables, which 

are designed for operating temperatures > +75°C 
(+167°F).  To meet GL requirements, unused terminal 
compartments should be closed.

5.5. Input (

1

1

1

1

, Figure 04, Figure 08)

The QUINT-DC-UPS is connected to the 24 V DC 

output of the power supply via the "Input +" and 
"Input -" terminal blocks. The output is isolated from the 
input by the internal diode. The stored power is only 
supplied to the output. The device is protected against 
overcurrent and short circuit by an internal input fuse.

Fuse

Further device protection is not required, as an 

internal fuse is present.

Solid

[mm

2

]

Stranded

[mm

2

]

AWG

Torque

[Nm]

1

1

1

1

Input:

0.5 - 16 

0.5 - 10 

20 - 6

1.2 - 1.5

2

2

2

2

Output:

0.5 - 16 

0.5 - 10 

20 - 6

1.2 - 1.5

3

3

3

3

Battery:

0.5 - 16 

0.5 - 10 

20 - 6

1.2 - 1.5

4

4

4

4

 

 

 

 

 

 

 

 

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

8

8

8

8

Signal: 

0.2 - 4

0.2 - 2.5

25 - 14

0.5 - 0.6

l

If the internal fuse is blown, this is 
most probably due to a device fault.
In this case, the device should be 
checked in the factory.

Figure 08

Содержание QUINT-DC-UPS/24DC/40

Страница 1: ...g is thus required for maximum system availability Three floating PDT contacts and three LEDs are provided for function monitoring which indicate all the operating states clearly So that relay signali...

Страница 2: ...harge current Battery presence check time interval Battery quality test time interval Memory Medium Nominal voltage Nominal capacity Charge current QUINT DC UPS 24DC 40 DC UPS Module U u F Type Order...

Страница 3: ...cations Signaling Power In OK Alarm Battery Mode Battery Charge Approvals Standards Electrical equipment of machines Electrical safety of IT equipment Industrial control equipment Shipbuilding Electro...

Страница 4: ...ully The QUINT DC UPS is a built in device Installation and startup must only be carried out by qualified personnel The relevant country specific regulations e g VDE DIN must also be observed Before s...

Страница 5: ...4 DC OK 24V 0 2A 11 21 12 13 2 11 Alarm Bat M ode Bat C harg e QUIN T D C U PS 24DC 20 Ord er No 28 66 23 9 Input Opera tional Voltage Output 24VDC 22A 22 5 3 0VDC 24VDC 20A APPROVALS Read in sta llat...

Страница 6: ...onnected For reliable and safe to touch connections Strip 10 mm 0 39 in from the input and output side connector ends and 7 mm 0 28 in from the signal connector ends To maintain UL approvals use coppe...

Страница 7: ...24DC type battery modules The following battery modules are recommended QUINT BAT 24DC 3 4AH Order No 2866349 QUINT BAT 24DC 7 2AH Order No 2866352 QUINT BAT 24DC 12AH Order No 2866365 When using QUIN...

Страница 8: ...ce remains off until remote shutdown is deactivated Connected loads are supplied as long as the supply voltage is present 6 Setting Options on the Device Fig 13 6 1 Buffer Time Setting Buffer mode can...

Страница 9: ...idling proof 7 2 Signaling Three floating PDT contacts and three indicators are provided for function monitoring xx xx Contact closed 1x Alarm 2x Battery Mode 3x Battery Charge x1 group contact x2 N C...

Отзывы: