PSR-CT
PHOENIX CONTACT
108366_en_01
X direction
-
Typical switch-on distance
7 mm, typical
Assured operation distance S
ao
Position C:
3 mm
Position D:
2 mm
Switching hysteresis
1 mm, minimum
2 mm, typical
Assured release distance S
ar
17 mm, maximum
Repeat accuracy
≤
10 %
Y direction
-
Typical switch-on distance
At 4 mm distance between the sensor and
actuator in the X direction
±6 mm, typical
Assured operation distance S
ao
1)
At 2 mm distance between the sensor and
actuator in the X direction
2)
At 1 mm distance between the sensor and
actuator in the X direction
Position C:
±4 mm
1)
Position D:
±3 mm
2)
Switching hysteresis
1 mm, minimum
2 mm, typical
Assured release distance S
ar
±15 mm, maxi-
mum
Repeat accuracy
≤
10 %
Z direction
-
Typical switch-on distance
At 4 mm distance between the sensor and
actuator in the X direction
±9 mm, typical
Assured operation distance S
ao
1)
At 2 mm distance between the sensor and
actuator in the X direction
2)
At 1 mm distance between the sensor and
actuator in the X direction
Position C:
5 mm
1)
Position D:
4 mm
2)
Switching hysteresis
1 mm, minimum
2 mm, typical
Assured release distance S
ar
±29 mm, maxi-
mum
Repeat accuracy
≤
10 %
Table 3-1
Minimum distances and switching distances
Actuation position
Travel
direction
Minimum dis-
tance in X direc-
tion
Switching distances with regard to respective
travel direction
C
D
X
Y
Z