7.6
Charging current control via analog CCR signal
The digital CCR input can be reconfigured to function as an analog input (see
).
Figure 7
-
6
Connection example 6
S1/DIP 1 = OFF
Charging station with Infrastructure Socket Outlet
S1/DIP 5 = ON
Charging current preset to 32 A
Locking
is carried out if a vehicle is detected.
The
charging process
starts if the locking feedback is available, switch k1 is closed, and
status C is present.
When changing the voltage at the analog CCR input, e.g., using a potentiometer, the max
-
imum charging current can be adjusted.
L N
PE GND 12V 12V
a
EN XR ML CCR IN OUT ERR CHG CON
C1 C2
A B SG
CP PP L1
D
L2
D
L0+ L0-
IO
R
ela
y
R
485
S
Outlet
Po
w
er
PWR
S1
S2
CON
ERR
CHR
M
RD
GN
YE
BN
N
PE
L, L1-L
3
2
3
0 V
1
3
5
24
6
1A
2A
7
8
1
3
2 A
S1
0
k1
EV-T2M3SE12-3AC...
EV-CC-AC1-M3-CBC-...,
connection of case B
Содержание EV Charge Control Basic
Страница 1: ...User manual EV Charge Control Basic Installing and starting up the charging controller ...
Страница 14: ...EV Charge Control Basic 14 68 PHOENIX CONTACT 106377_en_04 ...
Страница 34: ...EV Charge Control Basic 34 68 PHOENIX CONTACT 106377_en_04 ...
Страница 46: ...EV Charge Control Basic 46 68 PHOENIX CONTACT 106377_en_04 ...
Страница 69: ......