EV Charge Control Basic
18 / 68
PHOENIX CONTACT
106377_en_04
4.2
Mounting the PCB (EV-CC-...-PCB only)
WARNING: Dangerous contact voltage
Electrical shock from unprotected live parts.
Only mount the PCB when the device is disconnected from the mains.
Only operate the device in a charging station housing that corresponds to the applica
-
ble requirements for charging stations.
For mounting the PCB, four bore holes (4 mm in diameter) are provided.
Ensure that there are sufficient air clearances and creepage distances from the conductive
surfaces.
4.3
Mounting the housing (EV-CC-...-HS only)
WARNING: Dangerous contact voltage
Electrical shock from unprotected live parts.
Only remove the covering hood when the device is disconnected from the mains.
Only operate the device in a charging station housing that corresponds to the applica
-
ble requirements for charging stations.
Removing the covering hood
Figure 4
-
3
Removing the covering hood
The covering hood is not latched upon delivery. The covering hood must be removed in
order to configure the device.
•
To remove the latched covering hood, lift the side panel. To do so, insert the tip of a
screwdriver into the lowest slot.
B
A