Maintenance
4024_en_E
PHOENIX CONTACT
BL2 PPC ...100
1.
Remove the BL2 PPC ...100 from its mounting location and place it on a clean,
horizontal surface.
2.
Remove the six screws (1) securing the IPC chassis to the rear of the display.
Figure 5-2
IPC chassis removal from panel
3.
Carefully turn the IPC chassis over and set it on the back side of the display.
4.
Remove the screw securing the ground wire to the adapter plate.
5.
Remove the six screws securing the adapter plate to the rear of the chassis (see
Figure 5-1 for similar panel).
6.
Gently pry the adapter plate away from the chassis using a flat screwdriver. Turn the
adapter plate over, keeping the connected cables in the opening to the display, and set
it on the back of the display with the thermal pads facing up.
7.
Replace any desired components.
8.
Place the adapter plate on the chassis, making sure no cables are pinched. Secure the
plate using the hardware previously removed.
1
NOTE:
Do not move the IPC chassis away from the display. Cables are connected between the
IPC chassis and display.
NOTE:
Two sticky-backed thermal pads are located between the adapter plate and drive tray.
NOTE:
It is not necessary to disconnect the video cables to the display from the chassis.
Содержание Basicline 2 Series
Страница 1: ...User manual UM EN BL2 100 Basicline 2 configurable industrial PCs...
Страница 4: ...BL2 100 2 36 PHOENIX CONTACT 4024_en_E...
Страница 18: ...BL2 100 16 36 PHOENIX CONTACT 4024_en_E...
Страница 32: ...BL2 100 30 36 PHOENIX CONTACT 4024_en_E...
Страница 34: ...BL2 100 32 36 PHOENIX CONTACT 4024_en_E...
Страница 36: ...BL2 100 34 36 PHOENIX CONTACT 4024_en_E...