Application manual for PSRclassic and PSRmultifunction, and the modular safety relay system
PHOENIX CONTACT
102597_en_03
5.2.4
PSR-ESD/4x1/30 up to PL d/SIL 2
Two-channel laser scanner monitoring with manual reset (ESPE type 3)
Application example
–
Two-channel laser scanner monitoring
–
Cross-circuit detection via laser scanner
–
Manual reset (A1, S34)
–
Feedback of contactor contacts K5 and K6 at S34
–
Stop category 0
–
Monitoring of external contactors
–
Safety level of the example up to PL d (EN ISO 13849-1) and SIL 2 (EN 62061)
Figure 5-12
Two-channel laser scanner monitoring with manual reset
PSR-ESD/4x1/30
Order No.
2981800 with screw connection
2981813 with spring-cage connection
Technical data
–
24 V AC/DC
–
2 undelayed enabling current paths, 2 delayed enabling
current paths
–
Monitored manual start or autostart
–
Basic insulation
–
Cat. 4/PLe in accordance with EN ISO 13849-1, SILCL 3 in
accordance with EN 62061
K
5
K
6
M
K
6
M
(N)
(
L
1)
K
5
L+
S11
S12
S21
S22
13
23
37
14
24
38
47
48
(
)
<
0
,
1
0
,
5
1
3
5
10
20
30
(
)
A
1
A
2
S34
PSR
-E
SD/4x1/30
S35
(
)
(
)
OSSD
1
OSSD
2
F
1
K
5
K
6
S1
Reset
L
aser
scanner
type
3
(C
l
ock)
(C
l
ock)
Содержание 2702924