Operating the crimping tool
105555_en_07
PHOENIX CONTACT
15
English
2.5
Loading the taped ferrule
2.6
Removing the battery
The yellow indicator light flashes. The ferrule magazine is empty.
•
Remove the waste container and dispose of the insulation rem-
nants.
Opening the lid
•
Flip the lid upwards to open. There will be slight resistance
when doing this.
Removing the remnants of the tape
•
Push the slide towards the front of the device.
•
Hold the slide in this position and remove the remnants of the
tape. Please make sure that the remnants of the tape do not fall
into the guide shaft.
Inserting the taped ferrule
•
NOTE: Damage to the crimping tool
Never remove the battery during the crimping process or troubleshooting. The conductor
should be taken out before the battery is removed.
The green and red indicator lights flash simultaneously at short in-
tervals. The battery is empty and has to be charged.
Unlocking the battery compartment
•
Press the release button on the bottom of the crimping tool. The
battery springs into the removal position.
•
Remove the battery from the crimping tool.
Charging the battery
•