background image

N90-DRC/500 Specifications 

 
API 500 series compatible rack unit:

  

Class A (DSOP2) Output specs

.  Frequency response: 20Hz to 20kHz  +-  0.5dB,  

 

 

 

 

 

 

 

 

 

 

  

Maximum Output = +15dBu @ 1kHz, Noise = -90dB @ 20Hz to 20kHz. 
Input connections: XLR input

 on rear of API compatible rack 

Phoenix Audio’s unique Class A, transformer-less, True electronically 
balanced buffer amp input stage.

 

 

Compressor Section Rotary Controls

Threshold Settings: From +10db to -30db 
Ratio Settings: From 2 to 8 
Release Settings: Release time of 0.1 seconds to 3 seconds  
Compressor Section Switches 
Bypass : engages or bypasses compressor section 
Fast : Fast or auto attack times (1ms for fast or 15ms for slow/auto) 
Auto : Auto release of compression 
 

Gate Section Rotary Controls: 

Threshold Settings: From 0db to -40db 
Range Settings: From 40 to 10 
Release Settings: Release time of 0.1 seconds to 2 seconds  
 

Gate Section Switches: 

Link: Ability to link multiple modules (up to 8). 
Key: External input for gate section, connector is a TT Bantam connector 

Gate: Switches the Gate in and out  
 

Compression Meter:

 LED Metering. (Green = -3dbu, -6dbu -10dbu & -14dBu, 

Red= -20dBu and doubles as the 

Gate Active

 LED) 

Typical Headroom: 

+26dB on output stage. 

 

Содержание N90-DRC 500

Страница 1: ...it s sonic qualities as we are You are now the proud owner of a Compressor Gate that has the advantages of more than 40 years experience in audio engineering today s component and manufacturing techn...

Страница 2: ...essive curves are very kind There is no sudden change on passing the threshold and audio processing is virtually seamless Rapid release times become inappropriate and the 30 1 range provided is ample...

Страница 3: ...d to be driven by ear Each control knob indicates simply the range available and has a ring of marks to aid setting Only experience can determine optimum settings for the occasion and these may well i...

Страница 4: ...of 0 1 seconds to 3 seconds Compressor Section Switches Bypass engages or bypasses compressor section Fast Fast or auto attack times 1ms for fast or 15ms for slow auto Auto Auto release of compression...

Страница 5: ......

Страница 6: ...B over the threshold the compressor will only allow 1dB to pass through Fast Switch The Fast switch deals with attack times The N90 has an auto attack time built in that generally covers most situatio...

Страница 7: ...rack manual for information about how to link the pins When N90 s are linked via Pin 6 it is always the left most module that takes command when the units are in Link mode The Link switch must be swit...

Страница 8: ...of time between when the signal falls below the gate threshold and the gate releasing the signal Gate Switch Switching the gate switch down activates the gate circuit This illuminates the 20 Red LED t...

Отзывы: