Note:
Battery voltage must be below setting for longer than 2 minutes and up to 30
minutes for LVD to take effect.
Technical Data
Note:
The two voltage levels before/after the slash are valid for 12 V and 24 V systems
respectively.
Note:
Voltage and current specifications are direct current (DC) type.
Technical Data
ECO-N-10-T
ECO-N-20-T
System nominal voltage
12/24 V, auto recognition
Max. charge current
10 A**
20 A**
Max. load current
10 A**
20 A**
Range of Battery Voltage for Operation
9.0 to 15.5 V / 18.0 to 31.0 V
Float charge
13.8/27.6 V (25 °C)
Main charge
14.4/28.8 V (25 °C), 0.5 h (daily)
Boost charge
14.4/28.8 V (25 °C), for 2 h
Activation voltage <12.3/24.6 V
Charging Voltage Range
9.0 to 15.0 V / 18.0 to 30.0 V
Deep Discharge Protection
11.0/22.0 V
27
Содержание ECO-N-T Series
Страница 6: ...4 Sicher ung...
Страница 16: ...14 ECO N T Sicherer Betriebsbereich Nennlaststrom...
Страница 23: ...21 Fuse Install a fuse on the battery positive wire as close to the battery positive terminal as possible...
Страница 35: ...33 Fusi ble...
Страница 45: ...43 ECO N T SOA Safe Operating Area Corriente consumo nominal...
Страница 65: ...63 Fus vel...
Страница 75: ...73 SOA rea de prote o segura do ECO N T Corrente nominal consumidor...
Страница 77: ...ECO N T LED IP68 IP21 ECO N T 75...
Страница 78: ...CE CE 12 24 V 76...
Страница 79: ...1 2 3 4 mm2 ECO N T 1 5 ECO N T 10 15A ECO N T 20 30 A 77...
Страница 80: ...78...
Страница 81: ...12 24 V ECO N T GEL AGM 79...
Страница 82: ...3 LED LED LED LED 80 LED LED LED...
Страница 83: ...LED LED LED LED LED LED LED 11 0 22 0 V 12 8 25 6 V 81...
Страница 84: ...LED 1 2 3 4 30 V 30 V 15 5 V 1 2 4 6 3 4 200 3 s 82...
Страница 85: ...LED LED LED LED LED 15 5 V 83...
Страница 86: ...LED LED LED 84...
Страница 88: ...11 0 V 50 V 25 mV K 12 V 50 mV K 24 V 5 mA 40 to 60 C 4 000 m AGM WXHXD 100 x 61 x 20 mm 160 g IP68 IP21 86...
Страница 89: ...87 ECO N T SOA...