WelcomeEye Connect / Touch / 08/17
GB5
5. PRODUCT INSTALLATION
Advice and important instructions:
- To get the most out of your intercom panel, we recommend that you configure it before
permanently installing it (RFID, single or double family mode, one or two intercoms,
loudspeaker volume). Connecting it on the table may be necessary in order to verify that
the settings have been applied correctly.
- If you test your product before installing it, ensure that you do not test it with the intercom
panel and the monitor in the same room to avoid the video doorphone emitting a shrill
noise (feedback).
- Do not expose the camera lens to direct sunlight or a reflective surface.
- Tip: we recommend that you use a protective sheath when doing the cabling in order to
protect the cables against breakage and bad weather.
- For the WelcomeEye Connect model, so as to get the most out of your monitor’s WiFi
function, we recommend that you check that your WiFi network is accessible in your
planned installation location.
1. Wiring.
To avoid the risk of interference and malfunctions, do not run the video doorphone cable
through the same sheath as the electrical cables.
Warning
:
Do not double up the wires to increase the cross-section under any circumstances.
a. Connecting the video doorphone (monitor, intercom panel and camera)
Wires to use: 2 wires 0.75 mm
2
with 80 m length or 2 wires 1.5 mm
2
with 120 m length.
- Connect the wires according to the wiring diagram and following the chosen configuration.
- Refer to the label stuck to the back of the monitor and on the back of the intercom panel.
- Configure the switches on the back of the intercom panel as well as the monitor interface
according to the chosen configuration (see section 2 intercom configuration).
b. Connecting a gate motor
- The camera delivers a dry contact with no current, to be connected to the push button
control of your automatic opener.
- Connect directly to terminals 5 and 6 at the back of the intercom panel (no need to
observe polarity).
- The opening function will not work if the relevant intercom panel is displayed.
c. Connecting a strike plate or electric lock
Important
:
The strike plate or electric lock that you order must have a mechanical memory.
The strike plate current must not exceed 1.1A.
- Connect directly to terminals 7 and 8 at the back of the intercom panel (no need to
observe polarity).
- The opening function will not work if the relevant intercom panel is displayed.