Troubleshooting Guide
If a problem is suspected, first try recalibrating the luminaire to prompt an error message. The chart
below provides possible causes and remedies for various error messages and/or symptoms.
CAUTION:
Some troubleshooting is included for reference only. Performing remedies may void
product warranty. Refer to the Vari-Lite Limited Warranty card included with the product.
Table A-2: Troubleshooting Guide
Message
Symptom
Description
Possible Cause/Remedy
Lamp
Power
Douse
Lamp does not strike
upon start-up
Lamp Off option is config-
ured
- Reconfigure lamp startup option in Lamp config
menu.
n/a
Lamp douses frequently
Lamp Douse
Fan failure...
- check head and enclosure fans for proper
operation.
Ballast overheating...
- operating within the specified ambient
temperature?
- check enclosure vents for debris / dirt.
- check fan settings in menu.
- check enclosure fans for proper operation.
NOTE: Upon initial power up, ballast fans will run for
a few seconds and then operate as needed.
Enclosure vents must be clear of debris and dirt to
allow proper airflow.
n/a
Lamp will not strike
Lamp Strike Failure
Lamp cutout switch disengaged...
- check lamp cutout switches at lamp box and fan
ducts.
Bad lamp...
- replace lamp.
Low input voltage...
- check input power (must be 200 to 240 VAC).
n/a
Luminaire behaves
oddly
DMX Map Not Matched
Console library not set correctly...
- check console library matches DMX map of
luminaire.
n/a
Luminaire does not
power up
No power
Circuit not energized...
- verify circuit breaker (at source) is turned on.
Not plugged in...
- ensure A/C cable is connected to power source.
n/a
Self tests will not run or
software download does
not work from luminaire.
DMX Data Input
Detecting DMX data...
- disconnect DMX input cable.
n/a
No response to DMX
data
DMX Failure
DMX connector disconnected...
- check DMX DATA IN connection.
n/a
Erratic control of lumi-
naire
DMX Termination
No DMX termination or termination not correct...
- check for DMX terminator.
- Luminaire DMX address does not match console
patch.
Содержание VARI-Lite VL4000
Страница 1: ...VL4000 Spot Luminaire User s Manual ...
Страница 13: ...FOREWORD 02 9704 0001 D 03 February 2015 xi ...
Страница 14: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL xii 03 February 2015 02 9704 0001 D ...
Страница 18: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 4 03 February 2015 02 9704 0001 D ...
Страница 22: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 4 03 February 2015 02 9704 0001 D Notes ...
Страница 46: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 28 03 February 2015 02 9704 0001 D Notes ...
Страница 80: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 62 03 February 2015 02 9704 0001 D Notes ...
Страница 112: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 94 03 February 2015 02 9704 0001 D Notes ...
Страница 117: ......