Service Modes, Error Codes and Fault Finding
5.
This error is overwritten by the next player / inquiry command.
0x39
opc_power_calculation_er
ror
Error during OPC power calcula-
tion (samples are wrong)
0x3A
opc_test_zone_full_error
OPC can’t be performed because
test zone is full
0x3B
opc_bad_jitter_measurem
ent_error
The jitter measurement during
OPC samples readback failed
0x3C
opc_read_samples_error
An error occurred during OPC
readback sampling
0x3D
ropc_alpha_overflow_error The determined value for the op-
timum power is too high
0x3E
ropc_alpha_ref_current_er
ror
The alpha measurement refer-
ence current is wrong (IAN)
0x3F
ropc_alpha_gain_error
The alpha measurement alpha
gain is wrong
0x40
beta_over_under_flow_err
or
During the walking OPC a beta
over-/under-flow was detected
0x41
not_enough_calib_points_
error
Not enough valid calibration
points available for re-calibration
0x42
not_enough_power_error
The calculated power during re-
calibration exceeds max power
0x43
illegal_reading_speed_err
or
The selected speed is not al-
lowed for the requested com-
mand
0x44
servo_fatal_error
The actuator dissipation became
too high during a servo recovery
error
code
error
meaning
Содержание VAD8041
Страница 4: ...Directions For Use EN 4 VAD8041 3 3 Directions For Use Not applicable ...
Страница 14: ...EN 14 VAD 8041 6 Block Diagrams Waveforms Wiring Diagram Testpoints Overview TR 22005_001 070704 ...
Страница 30: ...EN 30 VAD 8041 7 Electrical Diagrams and Print Layouts ...
Страница 47: ...Spareparts List EN 47 VAD8041 10 10 Spareparts List 10 1 Exploded Views Basic Engine TR 22001_001 300604 ...
Страница 49: ...Spareparts List EN 49 VAD8041 10 DVD M TR 22003_001 300604 ...