background image

SL ParBlazer 100 UV Menu Tree

11

3. SL ParBlazer 100 UV Menu Tree

Figure 9: SL ParBlazer 100 UV Menu Tree

Installation & User’s Manual

SL ParBlazer 100 UV

Temperature

Firmware

RDM UID

001--512

000%--100%

 DMX 8Bit

OFF

 No

DMX Address

Manual Dimming

DMX Personality

Dimming Curve

DMX Fail

Default Setting

Manual

 55^oC

Linear Curve

Square Curve

 Rev1.00

0x405101020304

DMX 16Bit

S_Curve

PL_Curve

Last Hold

Manual

 Yes

Содержание SL ParBlazer 100 UV

Страница 1: ...SL ParBlazer 100 UV ...

Страница 2: ...5 Website www philips com showline The material in this manual is for information purposes only and is subject to change without notice Showline assumes no responsiblitity for any errors or omissions which may appear in this manual For comments and suggestions regarding corrections and or updates to this manual please visit the Showline website at or contact your www philips com showline nearest S...

Страница 3: ...e subject to tampering by unauthorized personnel The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition Do not use this equipment for other than intended use Refer service to qualified personnel WARNING You must have access to a mains circuit breaker or other power disconnect device before installing any wiring BE sure that power is disconnected by removin...

Страница 4: ... Connecting to the DMX512 Network Mounting Luminaire OPERATION AND PROGRAMMING LCD Display and Menu System LCD Display and Menu System Operation SL ParBlazer 100 UV Menu Tree Master Slave Operational Mode Dimming Curve Selection DMX CONTROL RDM PARAMETER IDs 8 Bit Mode 16 Bit Mode SL ParBlazer 100 UV DMX Mapping SL ParBlazer 100 UV RDM Parameter IDs CLEANING AND CARE Special Cleaning and Care Inst...

Страница 5: ...dditional product information and descriptions may be found on the product specification sheet Note The SL ParBlazer 100 UV luminaire works from 100 to 240 VAC auto ranging 2 Included Items Each SL ParBlazer 100 UV luminaire includes the following items SL ParBlazer 100 UV Luminaire SL ParBlazer 100 UV Luminaire Quick Start Guide 3 About this Manual Installation User s Manual SL ParBlazer 100 UV S...

Страница 6: ...arBlazer 100 UV OVERVIEW Safety Cable Anchor Point Figure 1 SL ParBlazer 100 UV Common Components Installation User s Manual DMX512 AC Input RDM Input DMX512 AC Output RDM Output Figure 2 LCD Display Menu System Note For Menu operation and programming details refer to LCD Display and Menu System on page 9 LEFT Arrow Button RIGHT Arrow Button CHECK MARK OK Button EXIT Button SL ParBlazer 100 UV ...

Страница 7: ... input connector refer to Connecting SL ParBlazer 100 UV to AC Power on page 6 2 Connecting Power Units can be powered in one of two ways Direct connection to an AC power source using an AC input cable For wiring of the AC input connector refer to Connection from the AC output of another SL ParBlazer 100 UV When using this method it is very important not to connect any other type of equipment devi...

Страница 8: ... Luminaire is straightforward A total of 3 wires conductors need to be brought to the unit The following wiring scheme is required Figure 3 SL ParBlazer 100 UV AC Input Output Connections Luminaire Brown Main Line 100 to 240VAC Blue Neutral Green Yellow Ground Earth Table 2 SL ParBlazer 100 UVAC Input Connections Installation User s Manual Wire Color Purpose AC Input AC Output SL ParBlazer 100 UV ...

Страница 9: ...ed Figure 4 SL ParBlazer 100 UV DMX512 Input Output Connections Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on page 1 DMX CONTROL on page 13 For SL ParBlazer 100 UV DMX Mapping refer to Figure 5 SL ParBlazer 100 UV DMX512 Connections Luminaire DMX512 DMX512 out from first to second luminaire DMX512 out to the next from console or control devi...

Страница 10: ... Dimensions on page 36 Note Mounting hooks clamps safety cables etc are sold separately or by others For mounting accessories available for this product refer to Accessories on page 3 Figure 6 Mounting the Fixture Hanging Applications Floor Mounting The SL ParBlazer 100 UV are designed to sit directly on its enclosure assembly base in a floor installation application When used in this type of appl...

Страница 11: ...ddress Manual Dimming Default Setting DMX Personality Temperature Dimming Curve Firmware DMX Fail RDM UID Note If there are multiple luminaires in a system changes would need to be made at each LCD Menu as desired Upon power up the LCD will display the main screen showing menu The User can use and to select then enter the desired function menu Figure 7 LCD Display and Menu System LEFT Arrow Button...

Страница 12: ...ure the menu options as required To navigate and access menu settings selections Step 1 Make sure unit is powered and turned on Step 2 Press the desired button as shown in Figure 8 to access menu categories Step 3 Use LEFT RIGHT arrow buttons to navigate through the various options and settings Step 4 Make changes as desired Press the CHECK MARK OK button to accept changes Figure 8 LCD Display and...

Страница 13: ...ee Installation User s Manual SL ParBlazer 100 UV Temperature Firmware RDM UID 001 512 000 100 DMX 8Bit OFF No DMX Address Manual Dimming DMX Personality Dimming Curve DMX Fail Default Setting Manual 55 oC Linear Curve Square Curve Rev1 00 0x405101020304 DMX 16Bit S_Curve PL_Curve Last Hold Manual Yes ...

Страница 14: ...Only one Master unit is allowed in this type of operation Figure 10 SL ParBlazer 100 UV Master Slave Configuration Master Unit Slave Unit Slave Unit Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on page 1 DMX CONTROL on page 16 For SL ParBlazer 100 UV DMX Mapping refer to DMX512 DMX512 out from first to second luminaire DMX512 out to the next f...

Страница 15: ...rBlazer 100 UV Luminaire Dimmer Curves PL Curve follows the dimming curve of Philips Selecon PL series LED luminaries DMX Value Lumen Output 0 Linear Curve DMX Value Lumen Output 0 S_Curve DMX Value Lumen Output 0 Square Curve DMX Value Lumen Output 0 PL_Curve PL_Curve Dimming Curve Selection 13 Installation User s Manual SL ParBlazer 100 UV ...

Страница 16: ... DMX512 control values when the SL ParBlazer 100 UV LED Table 4 provides DMX channel mapping of all DMX512 control values when the SL ParBlazer 100 UV LED Luminaire is in 8 bit DMX512 mode as set by the luminaire s menu system Luminaire is in 16 bit DMX512 mode as set by the luminaire s menu system Table 3 SL ParBlazer 100 UV DMX Channel Mapping 8 Bit Mode Table 4 SL ParBlazer 100 UV DMX Channel M...

Страница 17: ..._STATUS_REPORT_THRESHOLD Support required only if supporting Parameters beyond the minimum required set Support required for Manufacturer Specific PIDs exposed in SUPPORTED_PARAMETERS message 1 SL ParBlazer 100 UV RDM Parameter IDs The following tables outline and describe all the RDM parameters Ids associated with SL ParBlazer 100 UV LED Luminaires Table 5 SL ParBlazer 100 UV RDM Product Paramete...

Страница 18: ...O 0x0200 SENSOR_DEFINITION 0x0400 0x0600 0x0403 0x0603 0x00B0 LANGUAGE 0x00F0 DMX_START_ADDRESS 0x00A0 LANGUAGE_CAPABILITIES 0x00E1 DMX_PERSONALITY_DESCRIPTION 0x0090 FACTORY_DEFAULTS 0x00E0 DMX_PERSONALITY 0x0082 DEVICE_LABEL 0x0081 MANUFACTURER_LABEL 0x0080 DEVICE_MODEL_DESCRIPTION 0x0070 PRODUCT_DETAIL_ID_LIST 0x00C2 BOOT_SOFTWARE_VERSION_LABLE 0x0122 DEFAULT_SLOT_VALUE 0x0202 RECORD_SENSORS 0x...

Страница 19: ...hich shall be consistent across all products having a given Manufacturer ID See Table B 2 ANSI E1 20 2010 Status ID Message Value Data Value 1 Data Value 2 Status ID Description 8100H 00H 00H ALL OK Get Set Type Length Unit Prefix Min Max Default Description Allowed Allowed RDM Parameter IDs 1 NONE NONE DB NONE DB NONE 100 3 3 100 0 0 8A00H U8 0 DIMMER 1 8A0CH S8 0 DMX FAIL MODE 1 8AA1H S8 0 Dimmi...

Страница 20: ...naire that can be removed for cleaning The SL ParBlazer 100 UV special care when it comes to cleaning from lens assembly Additional care needs to be taken with the plastic components because they are much easier to scratch or damage than glass Note Reagent grade isopropyl alcohol is good to use on the SL ParBlazer 100 UV plastic optics with anti reflection coatings If you have any questions regard...

Страница 21: ...ondensing Humidity 20 to 40 Degrees C 4 to 104 Degrees F Ambient Temperature 20 Degrees 17 000 mW 40 degrees 100V to 240V 10 auto ranging 100 Watts max 50 60Hz DMX512 1990 DMX512A RDM On Board Menu Source Beam Angle Light Output Field Angle Input Voltage Power Consumption Frequency Control Protocols IP65 IP Rating Note Common model specifications shown For specific model specifications features an...

Страница 22: ...2 Luminaire Dimensions LUMINAIRE DIMENSIONS 20 Installation User s Manual SL ParBlazer 100 UV ...

Страница 23: ...21 Installation User s Manual SL ParBlazer 100 UV NOTE ...

Страница 24: ...2015 Philips Group C ...

Отзывы: