We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems
PTS7-1
1BHFPG
1FSJNFUFS5SPVHI3FDFTTFE%JSFDU-PVWFS-JHIU51FS'PPU4FDUJPO
$
Performance & Quick Calculators
85˚
75˚
65˚
45˚
55˚
0˚ 5˚ 15˚ 25˚ 35˚
600
750
450
900
050
300
0 deg
90
deg
180
deg
CANDLEPOWER CURVE
REPORT NO: LRL 499-5D
LAMPS: 1-FO32T8
EFFICIENCY: 46.7%
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
50
30
10
50
30
10
50
30
10
0
56
56
56
54
54
54
52
52
52
1
50
49
47
49
48
46
47
46
45
2
45
43
41
44
42
40
43
41
39
3
41
38
35
40
37
35
39
36
34
4
37
34
31
36
33
31
35
33
30
5
33
30
27
33
30
27
32
29
27
6
30
27
24
30
27
24
29
26
24
7
28
24
21
27
24
21
27
24
21
8
25
21
19
25
21
19
24
21
19
9
23
19
17
22
19
17
22
19
17
10
21
17
15
21
17
15
20
17
15
CANDLEPOWER SUMMARY
ZONE
Deg
0
45
90
135
180
180
0
0
0
0
0
175
0
0
0
0
0
165
0
0
0
0
0
155
0
0
0
0
0
145
0
0
0
0
0
135
0
0
0
0
0
125
0
0
0
0
0
115
0
0
0
0
0
105
0
0
0
0
0
95
0
0
0
0
0
90
0
0
0
0
0
85
39
15
2
2
2
75
153
90
5
3
3
65
440
120
13
8
9
55
560
338
79
34
14
45
669
532
288
64
32
35
754
705
512
103
55
25
885
833
677
225
104
15
969
949
778
386
285
5
950
920
837
704
620
0
833
833
833
833
833
ZONE
LUMENS
% BARELAMP
% LUMINAIRE
0-90
1354
46.7
100.0
90-180
0
0.0
0.0
0-180
1354
46.7
100.0
Quick Calculators
ONE SIDE MOUNTING
NO OPPOSITE WALL
1.5
63
2.5
33
3.5
22
4.5
18
76
51
33
23
18
15
5.5
16
6.5
15
7.5
14
51
45
35
28
23
19
8.5
12
9.5
12
40
38
33
27
23
20
0
2
4
6
8
10
12
DISTANCE FROM WALL, FEET
TWO SIDE MOUNTING
12 FT BETWEEN WALLS
1.5
76
76
2.5
50
50
3.5
41
41
4.5
38
92
73
65
73
92
38
5.5
37
37
6.5
35
35
7.5
34
72
71
69
71
72
34
8.5
33
33
9.5
32
63
66
65
66
63
32
0
2
4
6
8
10
12
DISTANCE FROM WALL, FEET
ONE SIDE MOUNTING
6 FT BETWEEN WALLS
1.5
72
39
2.5
43
45
3.5
33
45
4.5
28
85
68
43
5.5
26
40
6.5
24
37
7.5
22
60
55
33
8.5
21
30
9.5
19
49
48
28
0
2
4
6
DISTANCE FROM WALL, FEET
HORIZONTAL FC
VERTICAL FC
DIST
ANCE FROM CEILING, FT
NOTE:
Add to end of catalog nu
m
ber for desired ballast.
E81
= T8 Electronic 120v
E82
= T8 Electronic 227v
M71
= T8 Electronic Di
mm
ing Ballast 120v
M72
= T8 Electronic Di
mm
ing Ballast 277v
Ordering Instructions
Individual Fixtures:
1. Order nu
m
ber of FIXTURES.
2. Order one END PLATE SET per fixture.
Continuous Rows:
1. Deter
m
ine run length.
2. Use chart above to find catalog nu
m
bers. Each run ends with a telescoping unit.
3. Order END PLATE SET for each open run.
Square/Rectangle Patterns:
1. Consult plans and
m
ark locations for corners.
2. Calculate net footage of each run.
3. Deduct corner di
m
ension fro
m
each corner.
4. Deter
m
ine catalog nu
m
bers the sa
m
e way as a straight run.
Cat No.
PTS7T148
PTS7184
PTS7160
PTS7148
PTS7136
PTS7124
Size
27" to 48"
84"
60"
48"
36"
24"
Lamps
1-4 Foot
2-4 Foot
2-3 Foot
1-4 Foot
1-3 Foot
1-2 Foot
Type
Tele
Module
Module
Module
Module
Module
4 '3"-6'0"
1
1
5'3"-7'0"
1
6'3"-8'0"
1
7'3"-9'0"
1
8'3"-10'0"
1
1
1
1
9'3"-11'0"
1
1
10'3"-12'0"
1
1
1
11'3"-13'0"
1
12'3"-14'0"
1
1
1
13'3"-15'0"
1
1
1
14'3"-16'0"
1
1
1
15'3"-17'0"
1
1
1
16'3"-18'0"
1
2
17'3"-19'0"
1
1
1
18'3"-20'0"
1
2
1
19'3"-21'0"
1
2
1
1
20'3"-22'0"
1
2
1
21'3"-23'0"
1
2
1
22'3"-24'0"
1
2
1
23'3"-25'0"
1
3
24'3"-26'0"
1
2
1
25'3"-27'0"
1
3
1
1
1
26'3"-28'0"
1
3
1
1
27'3"-29'0"
1
3
1
28'3"-30'0"
1
3
1
29'3"-31'0"
1
3
1
30'3"-32'0"
1
4
31'3"-33'0"
1
3
1
32'3"-34'0"
1
4
1
1
33'3"-35'0"
1
4
1
1
34'3"-36'0"
1
4
1
35'3"-37'0"
1
4
1
36'3"-38'0"
1
4
1
37'3"-39'0"
1
5
38'3"-40'0"
1
4
1
39'3"-41'0"
1
5
1
40'3"-42'0"
1
5
1
1
41'3"-43'0"
1
5
1
42'3"-44'0"
1
5
1
43'3"-45'0"
1
5
1
44'3"-46'0"
1
6
45'3"-47'0"
1
5
1
46'3"-48'0"
1
6
1
1
47'3"-49'0"
1
6
1
1
48'3"-50'0"
1
6
1
49'3"-51'0"
1
6
1
50'3"-52'0"
1
6
1
1
51'3"-53'0"
1
7
52'3"-54'0"
1
6
1
1
1
1
1
1
1
Ordering Information
ONE LIGHT
180
deg
0 deg
90
deg
% WALL REFLECTANCE
ROOM CAVITY RATIO
ZONAL LUMEN SUMMARY