Lighting Systems

 PTS7-1

1BHFPG

1FSJNFUFS5SPVHI3FDFTTFE%JSFDU-PVWFS-JHIU51FS'PPU4FDUJPO

$

Sample Run, End Plate and Corner Block Accessories

Quarter Scale

6

5

1

2

4

3

Co

m

plete ordering instructions on back.

Example of Straight Run

Lighted

Telescoping

Unit 

84"

84"

60"

Example of Pattern Run

Telescoping
Unit

90° Inside  Corner

48"

60"

48"

(3 places)

135° Outside

PTS7C1350 Standard
PTS7C1350A Air

8 -1/2” (245.11c

m

)

135° Inside

PTS7C1351 Standard
PTS7C1351A Air

90° Outside

PTS7C900 Standard
PTS7C900A Air

90° Inside

PTS7C901 Standard
PTS7C901A Air

End Cap Set

PTS7EP Standard
PTS7EPA Air

14” (35.56c

m

)

Features

1.

2. Lamping: 

One T8 fluorescent la

m

p, as specified. Provided by others.

3. Reflector: 

Die-for

m

ed se

m

i-specular alu

m

inu

m

.

4. Louver: 

Se

m

i-specular anodized alu

m

inu

m

, 40° lengthwise by 30° 

m

ini

m

u

m

crosswise shielding. Supported along both edges by concealed fra

m

e of

extruded alu

m

inu

m

. Bold baffle, pris

m

atic lens, gold anodized louver, open or

egg crate louver available, consult factory.

5. Socket Channels: 

Die-for

m

ed, pre-painted steel held by support brackets and

allows for up to 6” (15.24c

m

) la

m

p overlap.

6.

Electrical

Specify 120 volt or 277 volt. 3 conductor, 18 gauge wire. Color-coded quick
connectors allow ease of connection for joiner 

m

odules. For special circuiting,

consult factory. Factory installed ballast disconnect allows the ballast to be
disconnected fro

m

 and reconnected to inco

m

ing power under load without turning

the entire circuit off.

Dimming: 

Advance Mark X, use Advance co

m

patible two-wire control (no extra

control lead required).

Mountings

Wall Adjustment Bracket

 - Allows for inconsistencies in wall straightness.

Die-for

m

ed steel used to 

m

ount syste

m

 to the wall.

Finish

Ceiling tri

m

 painted baked ena

m

el se

m

i-gloss white.

Options and Accessories

90° inside, 90° outside, 135° inside, and 135° outside corerns available.

Labels

UL, cUL and I.B.E.W.

11-1/4” (28.58c

m

)

7 -1/16”

(19.94c

m

)

1-5/16” (3.33c

m

)

8-1/4” (20.96c

m

)

1-1/2” (3.81c

m

)

1-1/2”
(3.81c

m

)

4-3/4” (12.07c

m

)

1-1/2” (3.81c

m

Housing: 

Die-for

m

ed steel, slotted for air return. Integral flanges at each end

strengthen the housing and per

m

it housings to be bolted together in continuous

runs and facilitate suspension of fixture. Concealed openings for heat extraction
and air return.

Ceiling Trim: 

Extruded alu

m

inu

m

 with integral aligner splines.

90° Outside Corner

8' 1/2”

(245.11c

m

)

8' 1/2”

245.11c

m

14" (35.56c

m

)

14" (35.56c

m

)

10'  2-1/4” (310.52c

m

)

9' 0” (274.32c

m

)

21' 10-3/4” (677.39c

m

)