background image

Job Information 

Type:

Job Name: 

Cat. No.: 

Lamp(s): 

Notes:

 

"JSQPSU3PBE'BMM3JWFS."t t'BY 

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

Lighting Systems

 PTS5-1

1BHFPG

1FSJNFUFS5SPVHI3FDFTTFE-JHIU51FS /PNJOBM4FDUJPO

$

Quarter Scale

Features

1. Housing:

Die-for

m

ed 20 gauge pre-painted steel. Integral heavy gauge bulk-

heads support housing and tri

m

, per

m

itting 

m

odules to be bolted together in

continuous runs and facilitate suspension.

2. Lamping: 

Continuous Rows:

1. Deter

m

ine run length.

2. Order the appropriate nu

m

ber of MODULES for the co

m

plete ROW.

3. Stagger rows 

m

ust be co

m

pleted with an adjustable 

m

odule. 

4. Non-stagger rows 

m

ust be co

m

pleted with an adjustable 

m

odule unless row

lengths are in precise 1 foot (30.48c

m

) intervals.

5. Order one END SET per ROW.

Labels

UL, cUL and IBEW

Ordering Instructions

Individual Fixtures:

1. Order nu

m

ber of MODULES required.

2. Order one END SET per MODULE.

(2-light only) 

3. Reflector:

Precision parabolic roll-for

m

ed se

m

i-specular alu

m

inu

m

.

4. Louver: 

Lift and shift straight blade louver constructed fro

m

 die-for

m

ed alu-

m

inu

m

  and painted to 

m

atch housing. Louver blades are 1” (2.54c

m

) high on

1-1/8” (2.86c

m

) centers. (Optional)

Mounting

“J” Rail is first 

m

ounted to the wall and the 

m

odules connect to the rail for 1/4”

(0.64c

m

) wall adjust

m

ent. Modules are hung fro

m

 suspension wires attached to the

fixture bulkheads and the structure above.

Electrical

Electronic Ballast:

Progra

mm

ed start, 3 conductor, 12 gauge wire. Color-coded

quick connectors allow easy connection for 

m

odular fixutres. Factory installed

ballast disconnect allows the ballast to be disconnected fro

m

 and reconnected to

inco

m

ing power under load without turning the entire circuit off.

Dimming:

T5 la

m

p uses PowerSpec® HDF. Use PowerSpec® HDF co

m

patible 

Emergency Battery Pack:

450 Lu

m

ens @ 90 

m

ini

m

u

m

.

three-wire control (extra control lead required).
T5 HO la

m

p uses Advance Mark X. Use Advance co

m

patible two-wire control (no

extra control lead required).

Cross-sectional one linear T5 fluorescent la

m

p. Provided by others.

Family

Lamps

Shielding

Voltage

PTS5

1

Length

Options

Blank

 = No Options

= Adjustable*

X4

  = 4 thru wires

X5

  = 5 thru wires

A4

  = Adjustable 4 thru wires*

A5

  = Adjustable 5 thru wires*

1

 = 1 La

m

p

S

 =  Standard

H

 =  HO

O

 =  Open

L

 = Lens

S

 =  Straight

Blade Louver

1

 = 120V

2

 = 277V

3

 = 347V

D1

 = 120V Di

m

.

D2

 = 277V Di

m

.

E1

 = 120V E

m

erg.

E2

 = 277V E

m

erg.

Lamp  Type

Module Ordering Information

* only available on Two-Foot, Three-Foot and Four-Foot versions. See length variations of adjustable fixtures on page 2.

2

 = Two-Foot

3

 = Three-Foot

4

 = Four-Foot

6

 = Six-Foot

8

 = Eight-Foot

7"

(17.78c

m

)

9 3/8" (23.81c

m

)

5 1/2" (13.97c

m

)

1

3

4

2

Отзывы: