2.3.3. 1 .
Checking and adjusting the band·pass curve of a.m. receivers
RF OUT
MA8211
Fig.
1 1.
Static adjustment of an AM receiver
2.3.3. 1 . 1 .
I.F. band-pass filters
- Connect the h.f. output of the P M 5324 to the connection point i ndicated in the trimming table of the
receiver via a 30 nF capacitor
.
- Adjust the frequency of generator P M 5324 to the intermediate frequency of the receiver.
- The output voltage should be as large as possible.
- Tune the receiver to the short wave end.
- Set the receiver to medium wave.
- If
the receiver has a ferrocepter, short-circu it the medium·wave ferrocepter coil.
- Screw out the cores or trimmers of the i.f. band filters (note the trimming table of the documentation).
- Adjust the adjusting elements of the i.f. band·pass filters so that the connected i ndicator shows maximum
deflection, in the sequence i ndicated in the trimming table.
2.3. 3. 1 .2.
I. F. rejector and absorption circuits
- Con nect the h.f. output of the generator to the aerial input of the receiver via the dummy aerial of Fig. 8.
- Adjust the output voltage of the generator to maximum.
- Switch the receiver to medium wave.
- If the receiver has a ferrocepter, short-circuit the medium wave ferrocepter coi l.
- Screw out the cores of the i.f. rejector· and absorption circuit.
- Adjust the cores so that the indication shows minimum deflection.
2.3.3. 1 .3.
RF and oscillator circuits
- Connect the h.f. output of the generator to the aerial input of the receiver via the dummy aerial of Fig. 8.
- Set the receiver to the wave range to be adjusted.
- Tune the receiver and the generator to the frequency to be adjusted.
- Adjust the cores and/or trimmers of r.f. and oscillator circuits to maximum deflection of the i ndicator.
- If necessary, repeat the adjusting procedure for every wave range at the long- and short wave end.
Содержание PM5324
Страница 1: ...HF Generator 100kHz 110MHz PM5324 9452 053 240 1 9499 450 05511 730801 1 01 ...
Страница 15: ...14 Fig 4 Front view Fig 5 Rear view ...
Страница 43: ...Fig 33 Front view with item numbers Fig 34 Bottom view ...
Страница 44: ...44 Fig 35 Top view Fig 36 Left side view ...
Страница 45: ...45 0 0 0 0 1 ji I I MAB225 Fig 37 Scale dri ve n ...