background image

© 2008 Philips Lighting Company. All rights reserved.
Printed in USA 9/08

P-5805-F

www. philips.com   

Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050

A Division of Philips Electronics North America Corporation

Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050

A Division of Philips Electronics Ltd.

Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental certification. 
Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.

Philips MasterColor

®

Ceramic Metal Halide Pulse Start ED 23

1

2

Lamps featuring ALTO

®

Lamp Technology

Ordering, Electrical and Technical Data

Rated

Approx

Approx

Color

Product

Nom.

Bulb

Pkg.

ANSI

LCL

MOL

Avg. Life

Initial

Mean

Temp.

Number Ordering Code

Watts

Finish

Base

Qty.

Code

(In.)

(In.)

(Hrs.)

1

Lumens

2

Lumens

3

(Kelvin)

4

CRI

21114-4

CDM70/U/PS/3K ALTO

70

Clear

Mogul

12

M143/M98/E

5

7

3

4

24,000

6200

4340

3000

85+

15492-2

CDM70/U/PS/4K ALTO

70

Clear

Mogul 

12

M143/M98/E 

5

7

3

4

24,000

5900

4150

4000

85+

21115-1

CDM100/U/PS/3K ALTO

100

Clear

Mogul

12

M140/M90/E

5

7

3

4

17,000

9000

6750

3000

85+

15493-0

CDM100/U/PS/4K ALTO

100

Clear 

Mogul 

12

M140/M90/E 

5

7

3

4

24,000

9000

6750

4000 85+

21117-7

CDM150/U/PS/3K ALTO

150

Clear

Mogul

12

M142/M102/E

5

7

3

4

24,000

13,000

9100

3000

85+

15494-8

CDM150/U/PS/4K ALTO

150

Clear 

Mogul 

12

M142/M102/E

5

7

3

4

24,000

13,000

9100

4000

85+

1) Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. 

It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average. 

2) Measured at 100 hours of life in vertical and horizontal operating positions.

3) Approximate mean lumen output at 40% of lamp rated average life. Measured in vertical and horizontal operating positions.

4) Approximate color temperature in Kelvin degrees

This product utilizes ALTO

®

Lamp Technology. ALTO products pass the US EPA's Toxicity Characteristic Leaching Procedure (TCLP) for non-hazardous waste status. 

Check state and local laws, rules,and regulations regarding disposal.

Above specifications subject to change without notice.  

RECOMMENDED WARNINGS, CAUTIONS, AND OPERATING INSTRUCTIONS

R

“WARNING:

These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet

radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for

more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will
automatically extinguish when the outer envelope is broken or punctured are commercially available.” This lamp
complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30
Canada:SOR/DORS/80-381)

If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible
injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject
it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the
outer bulb could cause glass to fly if the envelope is struck.

WARNING: 

The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures

up to 1000° C and can unexpectedly rupture due to internal or external factors such as a ballast failure or 
misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass
might be discharged into the surrounding environment. If such a rupture were to happen, 

THERE IS A RISK

OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. 

This lamp contains an arc tube with a filling gas containing not less than 25nCi of Kr-85 and 
is distributed by Philips Lighting Company, a division of Philips Electronics North America 
Corporation, Somerset, New Jersey, 08875

RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. 

Allowing lamps to operate until they fail is not advised and may increase the possibility of inner
arc tube rupture. 

CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND
FIRE RESULTING FROM AN ARC TUBE RUPTURE, THE FOLLOWING LAMP OPERATING
INSTRUCTIONS MUST BE FOLLOWED. 

LAMP OPERATING INSTRUCTIONS: 

1. RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not

advised and may increase the possibility of inner arc tube rupture.

2. Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical

shock and potential burn hazards.

3. Use only in an enclosed fixture capable of withstanding particles of glass having temperatures up to 1000°C.

4. Use only auxiliary equipment meeting Philips and/or ANSI standards. 

Use within voltage limits recommended by ballast manufacturer. 

A. Operate lamp only within specified limits of operation. 

B. For total supply load refer to ballast manufacturers electrical data.

C. All Pulse Start lamps require a socket rated to withstand a 4000 Volt pulse.

5. Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.

6. If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition 

of the bulb glass. 

7. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat. 

8. Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require 

several hours of operation, with more than one start. Lamp color is also subject to change under conditions of
excess vibration or shock, and color appearance may vary between individual lamps. 

9. Lamps may require 10 to 15 minutes to re-light if there is a power interruption. 

10. Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the 

contents or fragments. 

11. Use this lamp only in a fixture that contains a Pulse Start metal halide ballast and is specifically designed for

use with Pulse Start metal halide lamps. 

A

B

Dimensions

A (MOL) –––––––––––––––––––––––––7.75"/195mm
B (LCL) –––––––––––––––––––––––––––5.0"/127mm

LCL = Light Center Length

MOL= Maximum Overall Length

NEW

NEW

NEW

P-5805-F ED23.5.qxd:Layout 1  9/16/08  10:53 AM  Page 2