Solar Module
Orientation
Period
Autonomy
losses
South
(≈ optimal)
Annual
0%
Summer
0%
Winter
0%
East / West
Annual
-17%
Summer
-9.8%
Winter
-28%
North
Annual
-35.8%
Summer
-21.6%
Winter
-54.8%
ORIENTATION AND AUTONOMY
1.1 INSTALLATION GUIDELINES
To avoid a loss of autonomy and a malfunction:
• The luminaire must be installed horizontally and must never be tilted;
• The luminaire must be installed at the end of the post;
• The luminaire must be installed in an open space with no trees or structures
nearby, this could favour snow accumulation and shading;
• The solar module must be ideally oriented towards the south, otherwise see
table “ORIENTATION AND AUTONOMY”.
Failing to follow these recommendations can result in loss of system performance.
FACTORS AFFECTING AUTONOMY:
Lack of sunshine, very low ambient temperature, snow accumulation due to trees
or structures nearby, shading due to nearby trees or structures, solar module
orientation (see table), too many unplanned occupancy detections (road, unusual
activities and events), sunshine below the monthly averages, time delay too high
on the occupancy sensor.