E3 Series
G
ENERAL
D
UTY
T
HERMOPLASTIC
E
MERGENCY
L
IGHTING
Page 2 of 2
Philips Lightolier
e: [email protected]
t: (508)
679-8131
w: www.lightolier.com
E3 Series August 9, 2012
Specifications are subject to change without notice.
© Koninklijke Philips Electronics N.V., 2012. All rights reserved.
Job Information
Type:
Ordering Information
Series
6 V Lead Calcium
E3112
= 12 W
2
E3125
= 25 W
E3136
= 36 W
1
E3150
= 50 W
6 V Nickel Calcium
E31N25
= 25 W
E31N50
= 50 W
1
= One Lamp
Head
2
= Two Lamp
Heads
3
= Three Lamp
Heads
# of Heads
6 V Tungsten
S6
= 5.4 W
S7
= 7.2 W
S9
= 9 W
12 V Tungsten
S9
= 9 W
S12
= 12.5 W
S18
= 18 W
MR16 LED Lamp Heads*
12 V LED
M7F**
= 7 Watt, 35°
Lamp Heads
W
= White
B
= Black
Housing Color
A
= Ammeter
3
BD
= Battery Disconnect Switch
3
DL
= Damp Location Listed
3
EX
= Special Input Transformer (specify voltage &
frequency)
4
F1
= 120 VAC Input Fuse
3
F2
= 277 VAC Input Fuse
3
P1
= 120 VAC Power Switch
3
P2
= 277 VAC Power Switch
3
T
= Self-Testing Diagnostics
3
TA
= Audible Self-Testing Diagnostics
3
TD
= Time Delay, 15 Minutes
3
V
= Voltmeter
3
Factory Installed Options
3
Accessories (order as a separate item)
SDREMOTE
= Infrared Remote Test Device
PCS1
= Polycarbonate Vandal Shield
WG5
= Wire Guard
Note
1) Not available with DL option. 2) Only available with non-diagnostic models. 3) Only available with diagnostic electronic models. 4) Some option combinations
may impact UL listing, consult factory for specifics.
12 V Lead Calcium
E3225
= 25 W
E3236
= 36 W
2
E3250
= 50 W
12 V Nickel Calcium
E32N25
= 25 W
E32N50
= 50 W
Optics
Wall mounted 7.5' AFF, ‘S9’ 6 V 9 W Tungsten Lamps Represented
7.5 ft.
25 ft.
6 ft.
Average initial footcandles at floor = 1.08
Maximum initial footcandles at floor = 3.0
Minimum initial footcandles at floor = 0.3
Maximum to minimum ratio = 10.00
* The optics layout shown is intended to be used as reference only. Standard reflectances used were 80/50/20. Lightolier is not responsible for site specific conditions that
may alter the results.
0.3
0.3
0.2
1.2
1.1
0.4
2.4
2.3
0.7
2.3
1.8
0.6
1.6
1.0
0.4
0.9
0.6
0.4
0.7
0.6
0.5
0.9
0.6
0.4
1.4
0.8
0.4
2.3
1.5
0.5
2.6
2.4
0.8
1.6
1.7
0.9
.5
0.5
0.3
0.7
0.7
0.4
2.0
1.9
0.6
2.6
2.2
0.7
2.0
1.3
0.4
1.2
0.7
0.4
0.8
0.6
0.4
0.7
0.6
0.4
1.1
0.6
0.4
1.8
1.1
0.4
2.5
2.0
0.6
2.2
2.2
0.7
0.8
0.9
0.4
0.2
0.3
0.2
Blank
= Standard,
Non-Diagnostic Unit
SD2
= Diagnostic
Electronics
Model Designator
Electrical Specifications
Non-Diagnostic Models (60 Hz)
6 V Lead Calcium: 0.115 A (120 VAC), 0.050 A (277 VAC)
6 V NiCad: 0.160 A (120 VAC), 0.071 A (277 VAC)
12 V Lead Calcium: 0.126 A (120 VAC), 0.055 A (277 VAC)
12 V NiCad: 0.116 A (120 VAC), 0.051 A (277 VAC)
1 FC Average
Self-Diagnostics Models (60 Hz)
6 V Lead Calcium: 0.113 A (120 VAC), 0.055 A (277 VAC)
6 V NiCad: 0.157 A (120 VAC), 0.065 A (277 VAC)
12 V Lead Calcium: 0.331 A (120 VAC), 0.146 A (277 VAC)
12 V NiCad: 0.200 A (120 VAC), 0.094 A (277 VAC)
Blank
= No
Lamp Heads
* Lamp included per UL acceptance. ** UL testing restricts using any substitutes for this lamp option.