Service Modes, Error Codes, and Fault Finding
EN 14
L04E AB
5.
Table 5-3 Error codes overview
Note:
Errors 7, 8, 13, 14 are not applicable.
5.6
The Blinking LED Procedure
Using this procedure, you can make the contents of the error
buffer visible via the front LED. This is especially useful when
there is no picture.
When the SDM is activated, the LED will blink the contents of
the error-buffer:
•
When all the error-codes are displayed, the sequence
finishes with an 'on' LED blink of 1.5 seconds,
•
The sequence starts again.
Example
of error buffer:
12 9 6 0 0
After activating SDM, the following occurs:
•
1 long 'on' blink of 5 seconds to start the sequence,
•
12 short blinks followed by a pause of 1.5 seconds,
•
9 short blinks followed by a pause of 1.5 seconds,
•
6 short blinks followed by a pause of 1.5 seconds,
•
1 long 'on' blink of 1.5 seconds to finish the sequence,
•
The sequence starts again at 12 short blinks.
5.7
Protections
If a fault situation is detected, an error code will be generated;
and, if necessary, the television set will go into protection
mode. Blinking of the red LED at a frequency of 3 Hz indicates
the protection mode. In some error cases, the microprocessor
does not put the set in protection mode. The error codes of the
error buffer and the blinking LED procedure can be read via the
Service Default Menu (SDM), or via ComPair.
To get a quick diagnosis the chassis has three service modes
implemented:
•
The Customer Service Mode (CSM).
•
The Service Default Mode (SDM).
•
The Service Alignment Mode (SAM).
For a detailed description, see the "Customer Service Mode,
Service Default mode" and "Service Alignment Mode" sections.
Error
Device
Error description
Check item
Diagram
0
Not applicable
No Error
1
Not applicable
X-Ray / over-voltage protection (US only)
2411, 2412, 2413, 6404, 6411, 6412.
A2
2
Not applicable
High beam (BCI) protection
3404, 7405
A2
3
Not applicable
Vertical guard protection
3466, 7451, 7452, 7453, 7454
A2
4
Tuner UA1316/A
I2C error while communicating with 2nd tuner
1000, 5010 (PIP Module)
F2
5
Not applicable
+5v protection
7604, 7605
A5
6
I2C bus
General I2C error
7200, 3207, 3214
A4
7
Not applicable
-
-
-
8
Not applicable
-
-
-
9
24C16
I2C error while communicating with the EEPROM
7601, 3604, 3605
A5
10
Tuner
I2C error while communicating with the PLL tuner
1000, 5001
A3
11
TDA6107/A
Black current loop instability protection
7330, 3351, CRT
B1
12
SDA9488X
I2C error while communicating with the PIP processor
7242 (PIP Module)
F1
13
Not applicable
-
-
-
14
Not applicable
-
-
-
15
TDA9178T/N1
I2C error while communicating with LTI module
7610
H
16
TDA9887
I2C error while communicating with PIP_Demodulator
7201
F2
17
IBO Zapper
No Communication possible with IBO Zapper module
-
K
18
IBO Zapper
General error from IBO Zapper module
-
K
19
TDA1200
I2C error while communicating with SSD stereo sound decoder
7200
A4
20
TDA1200
I2C error while communicating with video cosmic in Hercules IC
7200
A4