Circuit Description
9.
In Standby, the power supply works in 'burst mode'. Burst
mode can be used to reduce the power consumption below 1
W at stand-by. During this mode, the controller is active
(generating gate pulses) for only a short time and for a longer
time inactive waiting for the next burst cycle.
In the active period, the energy is transferred to the secondary
and stored in the buffer capacitor C
STAB
in front of the linear
stabilizer (see Figure below). During the inactive period, the
load (e.g. microprocessor) discharges this capacitor. In this
mode, the controller makes use of the Safe-Restart mode.
Figure 9-13 Supply standby mode (burst mode)
The system enters burst mode standby when the
microprocessor activates the 'Stdby_con' line. When this line is
pulled high, the base of Q7541 is allowed to go high. This is
triggered by the current from collector Q7542. When Q7541
turns 'on', the opto-coupler (7515) is activated, sending a large
current signal to pin 3 (Ctrl). In response to this signal, the IC
stops switching and enters a 'hiccup' mode. This burst
activation signal should be present for longer than the 'burst
blank' period (typically 30 s): the blanking time prevents false
burst triggering due to spikes.
Burst mode standby operation continues until the
microcontroller pulls the 'Stdby_con' signal low again. The
base of Q7541 is unable to go high, thus cannot turn 'on'. This
will disable the burst mode. The system then enters the start-
up sequence and begins normal switching behavior.
For a more detailed description of one burst cycle, three time
intervals are defined:
t1: Discharge of V
CC
when gate drive is active. During the
first interval, energy is transferred, which result in a ramp-up of
the output voltage (V
STAB
) in front of the stabilizer. When
enough energy is stored in the capacitor, the IC will be switched
'off' by a current pulse generated at the secondary side. This
pulse is transferred to the primary side via the opto coupler.
The controller will disable the output driver (safe restart mode)
when the current pulse reaches a threshold level of 16 mA into
the Ctrl pin. A resistor R1 (R3519) is placed in series with the
opto coupler, to limit the current going into the Ctrl pin.
Meanwhile the V
CC
capacitor is discharged but has to stay
above V
UVLO
.
t2: Discharge of V
CC
when gate drive is inactive. During the
second interval, the V
CC
is discharged to V
UVLO
. The output
voltage will decrease depending on the load.
t3: Charge of V
CC
when gate drive is inactive. The third
interval starts when the UVLO is reached. The internal current
source charges the V
CC
capacitor (also the soft start capacitor
is recharged). Once the V
CC
capacitor is charged to the start-
up voltage, the driver is activated and a new burst cycle is
started.
Figure 9-14 Burst mode waveforms
9.6.3
Protection Events
The SMPS IC 7520 has the following protection features:
Demagnetization sense
This feature guarantees discontinuous conduction mode
operation in every situation. The oscillator will not start a new
primary stroke until the secondary stroke has ended. This is to
ensure that FET 7521 will not turn on until the demagnetization
of transformer 5520 is complete. The function is an additional
protection feature against:
•
saturation of the transformer,
•
damage of the components during initial start-up,
•
an overload of the output.
The demag(netization) sense is realized by an internal circuit
that guards the voltage (Vdemag) at pin 4 that is connected to
V
CC
winding by resistor R1 (R3522).
The Figure below shows the circuit and the idealized
waveforms across this winding.
Figure 9-15 Demagnetisation protection
Over Voltage Protection
The Over Voltage Protection ensures that the output voltage
will remain below an adjustable level. This works by sensing
the auxiliary voltage via the current flowing into pin 4 (DEM)
during the secondary stroke. This voltage is a well-defined
replica of the output voltage. Any voltage spikes are averaged
by an internal filter.
If the output voltage exceeds the OVP trip level, the OVP circuit
switches the power MOSFET 'off'.
Next, the controller waits until the 'under voltage lock out' level
(UVLO =
±
9 V) is reached on pin 1 (V
CC
). This is followed by a
safe restart cycle, after which switching starts again. This
process is repeated as long as the OVP condition exists. The
output voltage at which the OVP function trips, is set by the
demagnetization resistor R3522.
Demag
4
Ctrl
Gnd
Vcc Drain
HVS
Driver
Sense
3
2
1
5
6
7
8
Burst-Mode stand-by on/off
from microprocessor
Linear
stabilizer
V
STAB
V
µ
C
C
STAB
C
Vcc
V
CC
R
1
Current pulse
generator
V
IN
Basic Burst mode configuration
CL 16532020_081.eps
100401
V
(start)
V
(UVLO)
V
CC
V
STAB
I
L
Active/
inactive
t1
t2
t3
V
µ
C
Soft start
Burst mode waveforms
CL 16532020_082.eps
100401
R
1
R
2
D
V
CC
winding
I
(ovp)(demag)
I
(opp)(demag)
Demag
4
Ctrl
Gnd
Vcc
Drain
HVS
Driver
Sense
3
2
1
5
6
7
8
configuration
A
B
0V
OUT
S
Vcc
V
N
N
⋅
IN
P
Vcc
V
N
N
⋅
Demagnetization
V
GATE
V
WINDING
Magnetization
V
demag
Comparator
threshold
V
demag
0.7V
0V
-0.25V
www.freeservicemanuals.info
22/11/2016
Published in Heiloo Holland
Содержание L01.1U
Страница 10: ...Directions for Use EN 10 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 11: ...Directions for Use EN 11 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 12: ...Directions for Use EN 12 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 13: ...Directions for Use EN 13 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 14: ...Directions for Use EN 14 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 15: ...Directions for Use EN 15 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 16: ...Directions for Use EN 16 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 17: ...Directions for Use EN 17 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 18: ...Directions for Use EN 18 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 19: ...Directions for Use EN 19 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 20: ...Directions for Use EN 20 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 21: ...Directions for Use EN 21 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 22: ...Directions for Use EN 22 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 23: ...Directions for Use EN 23 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 24: ...Directions for Use EN 24 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 26: ...Directions for Use EN 26 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 27: ...Directions for Use EN 27 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 28: ...Directions for Use EN 28 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 29: ...Directions for Use EN 29 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 30: ...Directions for Use EN 30 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 31: ...Directions for Use EN 31 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 32: ...Directions for Use EN 32 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 33: ...Directions for Use EN 33 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 34: ...Directions for Use EN 34 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 35: ...Directions for Use EN 35 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 36: ...Directions for Use EN 36 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 37: ...Directions for Use EN 37 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 38: ...Directions for Use EN 38 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...
Страница 39: ...Directions for Use EN 39 L01 1U AC 3 www freeservicemanuals info 22 11 2016 Published in Heiloo Holland ...