Страница 1: ...Quick installation guide Philips InteGrade LED engine system for indoor environments and refrigerated cabinets 30 to 30 C 22 to 86 F June 2013 ...

Страница 2: ...low the appropriate safety procedures Before removing any lens covers or fluorescent lamps always first switch off or disconnect the mains power to the lighting system Take care not to damage the existing heating wiring if the LED product is installed in a freezer Do not use tape to fix this InteGrade LED product or LED profile in position please use the appropriate mounting clips Please note that...

Страница 3: ...Grade profile InteGrade profile M style InteGrade profile F style InteGrade connector InteGrade engine lock inline InteGrade mounting clip shelf arm InteGrade extension cable InteGrade Y cable InteGrade spacer cable InteGrade mounting clip under shelf InteGrade magnet for M style profile RH 90 2 9 mm 1 8 inch Phillips H0 screw driver Products and tools OFF ON 1 2 Start ...

Страница 4: ...4 1 4 3 3 2 2 1 1 2 1 2 1 2 1 2 Phillips HO screwdriver torque 10 to 15 cNm Connecting the LED InteGrade engines in the profile 3 ...

Страница 5: ... is properly fastened Engines can then be placed in infinite lines BUT should be powered in accordance with the instructions in this guide Each powered section should be locked in place by two lock in line s to ensure proper contacting of the engines and power cables Never attach separate profiles beneath individual connected engines Attach a single profile beneath two connected engines in order t...

Страница 6: ...tact Philips Parallel connection You can make any combination of 140 and 575 mm 6 and 23 inch engines but do not exceed the maximum total load on one driver and stay within the boundaries of the maximum load allowed for series connection see tables below The 20 W and 80 W driver should be built in Series connection with Xitanium 20W driver Xitanium 20 W driver logistic code 929000654006 Maximum qu...

Страница 7: ...B Philips LED Power Driver 20 W 24V DC 0 75 mm2 AWG 18 max 10 m 32 feet driver cable approx 0 3 m 12 inch Philips InteGrade cable per string together max 2 5 m 98 inch A B Example parallel connections more strings Example series connections one string InteGrade LED engine 140 mm 6 InteGrade LED engine 575 mm 23 1 string Wiring diagram with Philips InteGrade LED engines ...

Страница 8: ... Electronics All rights reserved Form No 3222 635 67102 US 30 30 LE 6590 A 06 2013 www philips com oem www philips com ledrefrigeration www philips com ledmodulesna NA Customer Support Technical Service Tel 1 800 372 3331 ...