iColor Flex LMX gen2 Product Guide
20
Connecting to the sPDS-60ca 24V and sPDS-480ca 24V Power/Data Supplies
Connect each leader cable to an available power port on the back of a power/data
supply housing.
Connecting to the PDS-60ca 24V Power/Data Supply
The PDS-60ca 24V is an IP66-rated power/data supply, suitable for use in damp and wet
locations. The following procedure describes how to connect and seal a PDS-60ca 24V
power/data supply for outdoor applications.
1. Remove the power/data supply cover.
2. Remove the cover of the transmitter PCA junction box by expanding the four tabs
on the side and sliding the cover from the base.
3. Connect line, common, ground, and data to the provided terminal block, then
replace the cover of the transmitter PCA junction box.
4. Connect the leader cable connector to an available port inside the power/data
supply housing.
sPDS-60ca 24V
sPDS-480ca 24V
77.8 mm
(3.06 in)
25 mm
(0.98 in)
16 mm
(0.63 in)
Transmitter PCA junction box dimensions
Blue
Stripe
Black
Blue
Red
+
Data
Data
–
Red
Blue
Blue/
White
Black
Red
Blue
Blue/
White
Black