background image

HB955/A

1. FLOOR PART  (item 48)

-  Remove the props (item 44) in the grip.
-  Remove the covers (item 33 and 45).

The cover on the flex side can only be removed last.

2. REMOTE CONTROL  (item 31)

-  Detach the cord clamp at the back of the cord holder and 

pull the connector loose.

3. WHEEL  (item 36)

-  Remove the covers (item 33 and 45).
-  Remove the locking plate and the nearest frame screw.
-  Push the shaft out of its clamping.

4.  STAND LOWER PART  (item 28)

-  Put the appliance in the lowest operating position 

(however, screw (

A

) must be visible) and tighten the 

ornamental screw (item 27)

-  Remove the covers from the floor part.
-  Detach the 8-core cable so that the cable can easily slide 

through the cable duct.

-  Remove the shafts (

B

).

-  Remove the 2 bearing bushes (item 29).
-  Pull the 8-core cable out of the stand tube to the point 

where the clamped joint between the cable bushing and the 
protecting sleeve can be unlocked.

-  Detach the 8-core cable by loosening the nut of the 

bushing a quarter turn.

-  Now turn the stand and the radiation units through so far 

that the covers (item 15/17) rest on the floor.

-  Remove screws (

A

) and separate the upper and lower part 

of the stand.

5.  STAND UPPER PART  (item 23)

-  Loosen the lower part of the stand as described 

under .4.

-  Hinge the radiation units outwards (the upper part of the 

stand rests on the floor).

-  Remove the housing parts and detach the wire connections.
-  The covers (item 15/17) can now be separated from the 

hinge part.

WHEN A HOUSING AND COVER ARE 
ASSEMBLED, SPECIAL ATTENTION SHOULD BE 
PAID TO THE POSITIONING OF THE UPPER 
BEARING BUSH 

(see exploded view).

6.  HPA and IR LAMP  (item 6 and 7)

-  Put the appliance in operating position.
-  Remove the 6 screws from the lamp unit in question.
-  Remove the cover (item 15 or 17).
-  Remove 4 reflector clamps.
-  Remove the reflector and take the lamp from the holder.

NB:  When checking or replacing lamps, pay attention to 

the following:

a.  HPA lamps only start burning when they have cooled 

down sufficiently.

b.  Never touch a lamp with your fingers.  Clean the lamp 

with a cloth moistened with alcohol, if necessary.

c.  After assembly the glass filter should be free from finger 

prints and dust.  Clean the glass filter with a cloth 
moistened with alcohol, if necessary.

d.  New HPA lamps may show colour differences.  This is 

not a defect, but a characteristic phenomenon of lamps 
of this type.  The discolourations disappear after a short 
period of use.

e.  Always use protecting goggles when looking in the 

direction of burning lamps.

7.  GAS SPRING  (item 18)

-  Let the radiation part slowly rise from its transport 

position.

-  Hinge the radiation units outwards and remove a 

decorative cap and spring fix at 

C

.

-  Now push the radiation part back into transport position.
-  Use a plastic hammer to tap the pin at C outwards.

NB:  CONTINUE TO EXERT PRESSURE ON THE 

STAND.

-  Hinge the radiation units inwards again and raise the stand 

slowly by means of the handle.

-  Now turn the stand and the radiation part through so far 

that the radiation units rest on the floor.

-  The gas spring is now unloaded so that pin (

D

) can be 

easily removed.

-  Assemble the new gas spring, the protecting bracket and 

cover and press the pin (

D

) back in place again.

-  Lift the radiation part by its handle and check whether the 

gas spring with pin (

E

) is correctly supported in the fork of 

the hinged part.

-  Press the hinged part against the spring pressure, moving 

the radiation part along at the same time until the whole 
unit is in horizontal position again.

-  Continue to exert pressure and hinge the radiation units 

outwards.

-  Assemble the pin at 

C

.

-  Put the appliance in operating position, and assemble the 

remaining clamps.

8.  POWER PCB  (item 34)

-  Pull the mains plug out of the wall socket.
-  Remove the cover (item 33, see under .1).
-  Replace the power PCB and connect all connectors.
-  Place the cover on the base. The display of the remote 

control will now show error code E06 or E05.

-  This indicates that the power PCB still needs to be 

programmed (code A05) for use in the HB955 according 
to the input in the table.

DISASSEMBLY AND AS REPAIR INSTRUCTION

3-7

Содержание HB955/A

Страница 1: ...ion can be set After pressing the key the display showing and the UV working hours will be shown After 750 operating hours an L will automatically appear on the display to indicate that the HPA lamps need to be replaced or the tanning time must be slightly increased The clock speed of the µ controller is derived from the 50 Hz mains frequency This frequency is also used to control the 8 triacs tha...

Страница 2: ...Radiation area 190 x 70 cm Output min UVX 36 meter 3 6 mW cm2 at 65 cm Protecting goggles 2x HB072 4822 690 80147 Safety CENELEC insulation class 2 UV type 3 Weight approx 37 kg MISCELLANEOUS No specific issues M4 L M3 M2 C11 T1 R9 N M1 R6 R5 Tr8 L L N IR C2 C4 C3 C1 Tr7 Tr6 Tr5 Tr4 Tr3 Tr2 M1 L4 B2 B4 L6 C7 L3 B3 B5 L7 C8 L2 B8 B6 L8 C9 L1 B9 B7 L9 C10 HPA 4 HPA 3 HPA 2 HPA 1 TCO2 N Re1 N SK3 TCO...

Страница 3: ...e cooled down sufficiently b Never touch a lamp with your fingers Clean the lamp with a cloth moistened with alcohol if necessary c After assembly the glass filter should be free from finger prints and dust Clean the glass filter with a cloth moistened with alcohol if necessary d New HPA lamps may show colour differences This is not a defect but a characteristic phenomenon of lamps of this type Th...

Страница 4: ...62 95120 4822 528 70519 4222 062 94600 4822 124 20701 Bearing bracket set Memo panel Remote control Flex holder Cover floorpart L Power module Wheel large Connecting block mains 4 s connector mains 4 s connector capacitors 9 s connector ballasts Fan complete Mains flex Orn Prop set Cover floor part R Ballast 400 W 230 V Bar grip Housing floor part Clamp Wheel small Capacitor 50 µF 250 V Capacitor ...

Страница 5: ...HB955 A EXPLODEDVIEW RADIATION PART C 3 4 5 9 8 18 20 10 11 13 12 14 6 7 1 2 15 17 16 23 22 25 19 24 26 27 A D E B B 28 29 21 5 7 ...

Страница 6: ...HB955 A EXPLODEDVIEW FLOOR PART 31 32 33 30 34 35 36 37 38 51 52 43 44 45 46 47 50 49 48 39 41 42 40 6 7 ...

Страница 7: ...D WHITE PURPLE YELLOW BROWN BLUE BROWN RED M2 N 1 2 L BLACK GREEN BLUE RED BLACK PURPLE GREEN YELLOW WHITE RED PURPLE GREEN YELLOW WHITE B4 RED BLACK B2 B5 RED C1 BLACK BLUE M1 M2 BROWN M3 M4 C3 BLUE C2 BLACK C4 BLUE BLACK B3 B6 RED BLACK B8 B7 RED BLACK B9 TCO1 M1 BROWN BLUE BLUE C1 C2 C3 N 230V 50Hz L CH only HPA 2 HPA 1 IR 2 IR 1 IR 4 IR 3 HPA 4 HPA 3 M3 BLACK BLACK 7 7 ...