background image

HB955/A

TECHNICAL INFORMATION

-  Input voltage 

:  230 V - 50 Hz

-  Input consumption 

:  approx. 2250 W

- Fuse 

: 16 A

-  UVA source 

:  4x HPA Flexpower 400-600

- Ballast 

: 4x 400 W

 : 

1x 

100 

W

-  Starter 

:  integrated soft start system

-  IR source 

:  4x IR 550 W

- Timer 

: digital 30 mins

-  Cooling 

:  1x fan floor part

 

:  2x fan tanning part

-  Radiation area 

:  190 x 70 cm

- Output (min)
  UVX-36 meter 

:  3.6 mW/cm2 at 65 cm

-  Protecting goggles 

:  2x HB072 - 4822 690 80147

-  Safety 

:  CENELEC insulation class 2

 : 

UV 

type 

3

-  Weight 

:  approx. 37 kg

MISCELLANEOUS

-  No specific issues.

M4

L

M3

M2

C11

T1

R9

N

M1

R6

R5

Tr8

L

L

N

IR

C2

C4

C3

C1

Tr7

Tr6

Tr5

Tr4

Tr3

Tr2

M1

L4

B2

B4

L6

C7

L3

B3

B5

L7

C8

L2

B8

B6

L8

C9

L1

B9

B7

L9

C10

HPA

4

HPA

3

HPA

2

HPA

1

TCO2

N

Re1

N

SK3

TCO3

SK2

C1

C2

C3

CH only

M3

M2

safety

C12

R7

R8

TCO1

µ

C

R10

IR

IR

4

IR

3

IR

2

IR

1

SK1

2-7

Содержание HB955/A

Страница 1: ...ion can be set After pressing the key the display showing and the UV working hours will be shown After 750 operating hours an L will automatically appear on the display to indicate that the HPA lamps need to be replaced or the tanning time must be slightly increased The clock speed of the µ controller is derived from the 50 Hz mains frequency This frequency is also used to control the 8 triacs tha...

Страница 2: ...Radiation area 190 x 70 cm Output min UVX 36 meter 3 6 mW cm2 at 65 cm Protecting goggles 2x HB072 4822 690 80147 Safety CENELEC insulation class 2 UV type 3 Weight approx 37 kg MISCELLANEOUS No specific issues M4 L M3 M2 C11 T1 R9 N M1 R6 R5 Tr8 L L N IR C2 C4 C3 C1 Tr7 Tr6 Tr5 Tr4 Tr3 Tr2 M1 L4 B2 B4 L6 C7 L3 B3 B5 L7 C8 L2 B8 B6 L8 C9 L1 B9 B7 L9 C10 HPA 4 HPA 3 HPA 2 HPA 1 TCO2 N Re1 N SK3 TCO...

Страница 3: ...e cooled down sufficiently b Never touch a lamp with your fingers Clean the lamp with a cloth moistened with alcohol if necessary c After assembly the glass filter should be free from finger prints and dust Clean the glass filter with a cloth moistened with alcohol if necessary d New HPA lamps may show colour differences This is not a defect but a characteristic phenomenon of lamps of this type Th...

Страница 4: ...62 95120 4822 528 70519 4222 062 94600 4822 124 20701 Bearing bracket set Memo panel Remote control Flex holder Cover floorpart L Power module Wheel large Connecting block mains 4 s connector mains 4 s connector capacitors 9 s connector ballasts Fan complete Mains flex Orn Prop set Cover floor part R Ballast 400 W 230 V Bar grip Housing floor part Clamp Wheel small Capacitor 50 µF 250 V Capacitor ...

Страница 5: ...HB955 A EXPLODEDVIEW RADIATION PART C 3 4 5 9 8 18 20 10 11 13 12 14 6 7 1 2 15 17 16 23 22 25 19 24 26 27 A D E B B 28 29 21 5 7 ...

Страница 6: ...HB955 A EXPLODEDVIEW FLOOR PART 31 32 33 30 34 35 36 37 38 51 52 43 44 45 46 47 50 49 48 39 41 42 40 6 7 ...

Страница 7: ...D WHITE PURPLE YELLOW BROWN BLUE BROWN RED M2 N 1 2 L BLACK GREEN BLUE RED BLACK PURPLE GREEN YELLOW WHITE RED PURPLE GREEN YELLOW WHITE B4 RED BLACK B2 B5 RED C1 BLACK BLUE M1 M2 BROWN M3 M4 C3 BLUE C2 BLACK C4 BLUE BLACK B3 B6 RED BLACK B8 B7 RED BLACK B9 TCO1 M1 BROWN BLUE BLUE C1 C2 C3 N 230V 50Hz L CH only HPA 2 HPA 1 IR 2 IR 1 IR 4 IR 3 HPA 4 HPA 3 M3 BLACK BLACK 7 7 ...

Отзывы: