background image

GC3660

PARTS LIST & ELECTRICAL DIAGRAM

RESISTOR

Blue

Red

Brown

LAMP

FUSE

N

L

E

INPUT

THERMOSTAT

HEATING
UNIT

ASO

4-5

Pos

Service code

Description

1

2
3
4

5
6
7
8
9

10
11

17
18

19
20
21
22
24

25
26
27
28

4239 021 39870
4239 021 41401
4239 015 54410
4239 025 98250
4239 015 55920

4239 021 53140
4239 010 11290
4239 026 36990
4239 026 37240
4239 000 07760

4239 000 09802
4239 000 10594
4239 000 09654
4239 026 13220
4239 021 53640

4239 021 57941
4239 021 58141
4239 015 55800
4239 021 50050
4239 021 54851

4239 026 36860
4239 026 33580
4239 026 33590

4239 021 54931

4239 021 53160

4239 026 36900
4239 026 36940
4239 026 10270
4239 021 54831
4239 021 57771

Soleplate mounted assy  230 V / 2200 W
Soleplate mounted assy  120 V
SOS seal
Ryton spacer
Dosing seal

Cover assy
Heat shield
Swivel moulded
Backplate moulded
Cord set  EU

Cord set  Singapore / Hong Kong
Cord set  Thailand
Cord set  Taiwan
Thermostat bush
Water tank & housing assy

Water tank & housing assy - Singapore
Water tank & housing assy - Taiwan
Tank top seal
Thermostat dial printed
Thermostat dial printed - Eng text

Inlay soft touch
Spray knob moulded
SOS knob molulded

Sub-inlay printed  &  Steam slider assy

Filling door assy

Backplate screw cover
Inlay cover moulded
Filling cup
ASO - 230 V
ASO - 120 V

= changed

Содержание GC3660

Страница 1: ...eight Net weight 1 59 kg Water advice In case you live in an area with hard water e g water hardness more than 8 dGH it is recommended to use a mixture of 50 tap water and 50 demineralised water Automatic energy saving 90 of the energy a steam iron uses is used to convert water into steam This steam iron with innovative mechanism in the handle makes sure that you still get high steam performance b...

Страница 2: ...ASSY 24 SUB INLAY PRINTED 22 WATER TANK HOUSING ASSY 11 SWIVEL MOULDED 7 CORDSET 9 Disassemble FILLING DOOR ASSY 24 Remove screw C Disassemble SUB INLAY PRINTED 22 Disassemble TANK TOP SEAL 17 Remove screw D1 D2 D3 Disassemble WATER TANK HOUSING ASSY 11 Disengage quick connectors of CORDSET 9 Remove screw E1 E2 Disassemble swivel column Disassemble SWIVEL MOULDED 7 Disassemble CORDSET 9 COVER ASSY...

Страница 3: ... of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastane polyamide polyproylene 2 dots 100 160 130 30 Cupro polyester silk triacetate viscose wool 3 dots 140 21...

Страница 4: ...26 33580 4239 026 33590 4239 021 54931 4239 021 53160 4239 026 36900 4239 026 36940 4239 026 10270 4239 021 54831 4239 021 57771 Soleplate mounted assy 230 V 2200 W Soleplate mounted assy 120 V SOS seal Ryton spacer Dosing seal Cover assy Heat shield Swivel moulded Backplate moulded Cord set EU Cord set Singapore Hong Kong Cord set Thailand Cord set Taiwan Thermostat bush Water tank housing assy W...

Страница 5: ...GC3660 EXPLODED VIEW MAX C D1 D2 D3 F3 F2 F1 A E1 B1 E2 B2 24 17 11 8 26 28 19 20 21 22 6 27 5 4 3 7 9 Swivel column 25 18 2 1 10 5 5 ...

Отзывы: