REPAIR INSTRUCTIONS

-  Due to the high wattage of the iron, only the specified cord set must be used.

-  Should damage be observed on the 

CORDSET 22

, it must be replaced.  

Continued usage is not allowed.

-  After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as 

laid down & officially established at this moment.

-  The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. 

Soleplate temperature

Check that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 minutes. 
The table below shows the temperature requirement.

Marking

Soleplate temperature (Deg C)

Material, for example

Test-
point

==

Minimum Maximum N Tolerance

 (1 

dot)

  70

120

  95 ± 25

Acetate, elastane, polyamide, polyproylene

••

 (2 

dots)

100

160

130 ± 30

Cupro, polyester, silk, triacetate, viscose, wool

•••

 (3 dots)

140

210

175 ± 35

Cotton, linen

2. 

Leakage current

Check that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.
IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. 

Water leakage / Functionality

Check that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working properly.

4. 

Loose part

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

Содержание GC2810

Страница 1: ...CAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power 2000 W Dimension F box 328 mm x 129 mm x 163 mm Width x Depth x Height Product net weight 1 175 kg Water Advice In case you live in an area with hard water e g water hardness more than 8 dGH it is recommended to use a mixture of 50 tap water and 50 demineralized water Powerglide Soleplate Silver solgel coating for more robust scratch resis...

Страница 2: ...RINTED 17 Disassemble INLAY PRINTED 17 Disconnect 2x quick connectors of LAMP ASSY 5 Disassemble LAMP ASSY 5 THERMOSTAT DIAL PRINTED 21 WATER TANK ASSY 7 COVER 3 INSULATION SHEET 23 DOSING SEAL 13 SOS SEAL 14 SOLEPLATE MOUNTED ASSY 1 Disassemble THERMOSTAT DIAL PRINTED 21 Remove screws C 3x Disassemble WATER TANK ASSY 7 Remove screws D 3x Disassemble COVER 3 Note for re assembly Please ensure that...

Страница 3: ... minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastane polyamide polyproylene 2 dots 100 160 130 30 Cupro polyester silk triacetate viscose wool 3 dots 140 210 175 35 Cotton linen 2 Leakage current Check that leakage current is within IEC requirement Measure...

Страница 4: ...239 021 50280 4239 021 51910 4239 026 34480 4239 026 34650 4239 021 53730 4239 021 53540 4239 000 08850 4239 000 08670 4239 010 10290 4239 026 34490 Soleplate mounted assy 230 V 2000 W Ryton ring Cover molded Thermostat bush Lamp assy Tank top seal Water tank assy GC2810 Korea Australia Dosing seal SOS seal SOS knob Spray knob Inlay printed Filling door assy Backplate molded Ball swivel Snow white...

Страница 5: ...GC2810 5 5 EXPLODED VIEW B A D1 D2 D3 C1 C2 C3 22 19 5 2 1 4 7 20 16 24 15 18 23 3 13 14 6 21 17 ...

Отзывы: