b) Check Current_ON
- Turn the mobile on.
When the mobile is ON (backlight activated) the current measured must be :
75 < I (mA) < 125
This measurement has to be operated during first seconds after switch on.
c) Check Current_maximum
- Press on OK to activate Page selection. Press the Key 1 and then OK to select Page 1
- Press on Key 4 to select Antenna test. Press on the left arrowhead of the Compass Key as much times as
necessary to reach level 5.
(The mobile is now set at his maximum emission level)
When the mobile is emitting (backlight ON) the current measured must be :
100 < I (mA) < 200
- Remove the battery.
- Gently slide the card out away from the Product