DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- Open the appliance, first pull off the Atilla insert, after that
screw (
A
) under the insert can be removed with a
screwdriver
- After removing the filtercover the second screw (
B
) for
releasing the backpanel can be removed.
- The dustcover, button panel, bumper and the PCB’s can
now easily be removed.
- The upperhousing (dustc motorhousing) can be
released by removing 6 screws (
C
).
- The wires for the motor are placed under the sealing ring of
the motor.
- The sealing ring is placed in two grooves, which are made in
the lower housing.
- When you re-assemble then make sure that the wires for the
motor are placed underneath the sealing ring.
REPAIR INSTRUCTION
- Cotton dustbags, are used in countries in which paper
dustbags are not available.
- If the reel half spring unit is replaced, shaft
F
must be
lubricated with
silicone grease
. Do not apply any silicone
grease to or spill any grease on terminals (
26
) or conductors
(
25
).
- The cord winder spring must be tensioned to the maximum
level and then be rewound approx. 1.5 turn.
-
Item 8
, air valve, opens to cool the motor if the air
displacement is too low or if the airflow is blocked.
- When the vacuum cleaner is used to suck up fine dust the
pores of the dustbag may become clogged, causing the
passage of air through the dustbag to become obstructed.
As a result, the dustbag-full indicator will indicate that the
dustbag needs to be replaced, eventhough the dustbag is not
full at all.
ELECTRICAL DIAGRAM
MOTOR
POWER
MODULE
Black
Black/White
Brown
CORD WINDER
Blue
M
2-6