
Diagnostic Software
5.
Example (AV2)
DS:> 930
093006: This nucleus is not supported by the engine
Error @
Example (AV3)
DS:> 930
093000:
Test OK @
Nucleus Name
DS_BE_AdjustLaserControl
Nucleus Number
931
Description
Adjust the DVD-M (with the OPU) with PCBA. (So adjusts the two PCBS to each other)
Technical
-
Check if an AV2 or AV3 is connected
-
In case of an AV2 display a “not supported” message
-
In case of an AV3 adjust the DVD-M (with the OPU) with PCBA by sending a
S2B command to align the PCBs to each other.
Execution Time
30 seconds
User Input
None
Error
Number
Description
93100
The command executed successfully
93101
There was a time-out while communicating
93102
The Basic Engine returned an unexpected result
93103
The BE returned an error code
93104
No acknowledge received from BE
93105
Communicating with the Basic Engine failed
93106
Unable to enter service mode
93107
This nucleus is not supported by the engine
Example (AV2)
DS:> 931
093107: This nucleus is not supported by the engine
Error @
Example (AV3)
DS:> 931
093100:
Test OK @
http://www.jdwxzlw.com/?fromuser=华盛维修
家电维修资料网,免费下载各种维修资料