Nucleus Name
DS_ASP_KeyBoard
Nucleus Number
1612
Description
This nucleus checks all keys of the keyboard by having the user confirm the
key-code displayed of all keys. If the user presses ‘a’ or ‘A’ the test is aborted.
If the user presses ‘o’ or ‘O’ the test is indicated as OK.
If the user holds down ‘PLAY’ for more than a second the test is indicated as
OK, if the user holds down ‘RECORD’ the test is indicated as failed.
Indicate the number of keys pressed to the user, both in the terminal logging
and on the display.
Technical
-
Initialise the display.
-
Display the key pressed by the user on the display.
-
Monitor the service port for an abort and get the next key pressed.
-
Update the display and repeat previous steps until user stops / confirms.
-
Display the number of keys that were pressed.
Execution Time
Depends on the user.
User Input
None
Error Number
Description
161200
Checking all keys succeeded
161201
IIC-bus communication failed
161202
The user signals a failure of the keyboard
161203
The user aborted the test
Example
DS:> 1612
161200: 3 keys were pressed.
Test OK @
Nucleus Name
DS_ASP_RemoteControl
Nucleus Number
1613
Description
This nucleus checks the interface to the remote control by having the user
confirm the key-code displayed.
At least one key must be tested.
If the user presses ‘a’ or ‘A’ the test is aborted. If the user presses ‘o’ or ‘O’ the
test is indicated as OK.
If the user holds down ‘PLAY’ for more than a second the test is indicated as
OK, if the user holds down ‘RECORD’ the test is indicated as failed.
Indicate the number of keys pressed to the user, both in the terminal logging
and on the display.
Technical
-
Initialise the display.
-
Display the key pressed by the user on the display.
-
Monitor the service port for an abort and get the next key pressed.
-
Update the display and repeat previous steps until user stops / confirms.
-
Display the number of keys that were pressed.
Execution Time
Depends on the user.
User Input
None
Error Number
Description
161300
The test succeeded
161301
IIC-bus communication failed
161302
The user signals a failure of the remote control
161303
The user aborted the test
Example
DS:> 1613
161300: 4 keys were pressed.
Test OK @
Содержание DVDR5350H/05
Страница 160: ...EN 160 3139 785 31532 7 Circuit Diagrams and PWB Layouts Layout HDMI Top View 3103 603 30587 topview pdf 2006 09 04 ...
Страница 161: ...EN 161 3139 785 31532 Layout HDMI Bottom View 7 Circuit Diagrams and PWB Layouts 3103 603 30587 btmview pdf 2006 09 04 ...
Страница 162: ...EN 162 3139 785 31532 7 Circuit Diagrams and PWB Layouts Notes ...
Страница 177: ...EN 177 3139 785 31532 9 Circuit and IC description IC7203 NJM2267M Dual Video 6dB Amplifier BLOCK DIAGRAM Figure 9 11 ...