DIAGNOSTIC SOFTWARE : SCRIPT INTERFACES
GB 52
DVD 950
7.
7.3.4
LOOP TEST
At the start of the loop test, the display will show the result of
the interactive player test:
Figure 7-30
The left side of the display contains a 3-digit code, which can
have a value between 000 and 111. These values are to be
interpreted as follows:
Figure 7-31
The loop test will perform the same nuclei as the dealer test,
but it will loop through the list of nuclei indefinitely. The display
of the DVD player will display not only the three digits indicating
correct/faulty modules and the last found error code (as
mentioned, faults are detected as far as they can be within the
scope of the diagnostic software), but also a loop counter
indicating how many times the loop has been gone through.
Example:
Figure 7-32
The number after the hyphen indicates the number of times the
loop test has been performed; the 4 digits at the right side of the
display show the last error that was found when running the
loop test: the leftmost two digits of this code indicate which
nucleus resulted in a fault; the rightmost two digits refer to the
faultcode within that nucleus. For further explanation of this
error code, see list of error codes below.
Figure 7-33
CL 96532065_030.eps
120799
Displayed
Value
Indication for each module
Basic Engine
Mono
PCB
Display
PCB
000
ok
ok
ok
001
ok
ok
faulty
010
ok
faulty
ok
011
ok
faulty
faulty
100
faulty
ok
ok
101
faulty
ok
faulty
110
faulty
faulty
ok
111
faulty
faulty
faulty
CL 96532065_031.eps
120799
FAULTY
MODULE(S)
LOOP
COUNTER NUCLEUS ERROR
CL 96532065_032.eps
120799
ERROR CODES LOOP TEST
ERROR CODE
NUCLEUS NUMBER
ERROR DESCRIPTION
0601
6
Calculated checksum of FLASH is not correct
0901
9
The DVD DRAM is faulty
1101
11
I2C bus busy before start
1102
NVRAM access time-out
1103
No NVRAM Acknowledge
1104
NVRAM reply time-out
1201
12
I2C bus busy
1202
I2C bus not working
1203
Slave controller not responding
1204
Slave response is not correct
1301
13
Parity error from basic engine to serial
1302
Parity error from serial to basic engine
1303
No communication between serial and basic engine
1304
Communication time-out error
1601
16
The SDRAM is faulty
5201
52
I2c bus busy
5202
I2c bus not working
5203
Colour setup controller not responding
5204
Colour setup controller response not correct
5401
54
I2c bus busy
5402
I2c bus not working
5403
Scart switch controller not responding
5404
Scart switch controller response not correct
CL96532126_021.eps
261099