You can make use of the “Basic Scheduler” tab to modify start and end time as well as intensity factor of the 
existing schedules. Make your adjustments and press “Apply” to alter the schedule. Do not forget to press 
“Save to controller” to program the changes into the controller.

 

In the tab “Schedule editor” you can create a new “Custom 1” schedule. You can use one of the default sched-
ules as a baseline and save the modified schedules to “Custom 1” or “Custom 2” by clicking “Save schedule”. 

 

In this same menu, you can also alter the default name of “Custom 1” and “Custom 2”

 

If you want to alter individual points in the schedule you can “add” or “remove” time points. 

5/12

Содержание CoralCare

Страница 1: ...CoralCare Controller Gen2 Software manual desktop application ...

Страница 2: ...he application and click on the message not connected in the bottom left hand corner of the appli cation Alternatively click on device in the task bar and then click on open device to go to the same device connec tion window If you connected your controller via the USB cable to your computer you can press refresh and should be able to select your device in the pull down menu USB Then click Connect...

Страница 3: ...om the controller and will check if the time is programmed correctly If this is out of sync with the time settings of your desktop the software will load the Set device time screen Press refresh to check the time which is programmed in the controller If you want to change the time you can enter a custom day and time manually or synchronize the time with your computer Make sure to check your time z...

Страница 4: ...ght intensity for both channels programmed in Cus tom1 and Custom2 If you want to use a 3rd party aquarium computer to control the CoralCare fixtures you need to click 0 10V Mode and press Save to controller All other schedule options become unavailable in this mode When the application is started and the controller connected it displays the active schedule also mentioned in the bottom bar You are...

Страница 5: ...oller to program the changes into the controller In the tab Schedule editor you can create a new Custom 1 schedule You can use one of the default sched ules as a baseline and save the modified schedules to Custom 1 or Custom 2 by clicking Save schedule In this same menu you can also alter the default name of Custom 1 and Custom 2 If you want to alter individual points in the schedule you can add o...

Страница 6: ...ow 50 warm and 50 cold This effec tively means that both channels are dimmed to 50 output If the color slider is set to the right and the intensity is set to 100 the color temperature variables show 0 warm and 100 cold This effectively means that the white channel is disabled and the blue channel is burn ing at 100 Setting the intensity to 50 will result in the blue channel being dimmed to 50 Roun...

Страница 7: ... on and at what color point you want it to start Set the intensity at 0 for the first point Add a second point and again define time color and intensity The light settings will calculate all steps time color and intensity between these points and make sure the change in light settings runs smoothly 7 12 ...

Страница 8: ...ther reefers to show how you have set up your 24 hour schedule The settings have not yet been saved in the controller The settings will be transmitted to the controller when you click Save to controller If the luminaires are connected to the controller and power is enabled the live mode option can be used to experience the levels that are set in the scheduler application Live mode can be enabled b...

Страница 9: ...atization period towards the active schedule After the acclimatization period the active schedule will remain This is typically imple mented when installing new lamps with a new aquarium or when new corals are added to an existing tank Acclimatization factor refers to the amount of light reduction to start the process with Acclimatization period refers to the time it takes for the light intensity ...

Страница 10: ...will be saved in the internal memory and will nev er be lost The actual time will continue to be correct up to two days after disconnection of the power from the USB After two days the time should be re programmed via the PC application The internal clock of the device has a maximum deviation of 15 minutes a year We therefore recommend you re program the time of the controller on a yearly basis Di...

Страница 11: ...11 12 ...

Страница 12: ...www philips com coralcare 800 7445 4775 1 800 555 0050 Last update 21 04 20 Signify I B R S C C R I Numéro 10461 5600VB Eindhoven the Netherlands 2020 Signify Holding All rights reserved Europe US ...

Отзывы: