![Philips ColorBlast 12 Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/philips/colorblast-12/colorblast-12_quick-manual_310174004.webp)
ColorBlast Product Guide
4
Center Beam fc
Beam Width
4.0 ft
8.0 ft
12.0 ft
16.0 ft
20.0 ft
24.0 ft
1708 fc
427 fc
190 fc
107 fc
68 fc
47 fc
0.7 ft
1.3 ft
2.0 ft
2.7 ft
3.4 ft
4.0 ft
0.7 ft
1.4 ft
2.0 ft
2.7 ft
3.4 ft
4.1 ft
�
�
Vert. Spread: 9.6º
�
�
Horiz. Spread: 9.7º
Illuminance at Distance
ColorBlast 12
10° beam angle
Candela Table
0
5
15
25
35
45
55
65
75
85
90
0 22.5 44 67.5 90
27343
12774
458
157
114
55
21
2
1
0
0
27343
13162
473
156
116
58
21
2
1
0
0
27343
13077
464
153
113
56
21
2
1
0
0
27343
12960
459
154
114
56
21
2
2
0
0
27343
12942
465
152
111
56
21
2
1
0
0
Polar Candela Distribution
RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio
Effective Floor Cavity Reflectance: 20%
RCC %:
80
70
50
30
10
0
RW %:
RCR: 0
1
2
3
4
5
6
7
8
9
10
70 50 30
0
1.19 1.19 1.19 1.19
1.15 1.13 1.12 1.10
1.12 1.09 1.06 1.04
1.09 1.05 1.02 .99
1.06 1.01 .98 .95
1.04 .99 .95 .92
1.02 .96 .93 .90
1.00 .94 .91 .88
.98 .92 .89 .86
.96 .91 .87 .85
.95 .89 .86 .84
70 50 30
0
1.16 1.16 1.16 1.00
1.13 1.11 1.10 .98
1.10 1.07 1.05 .95
1.07 1.03 1.01 .93
1.05 1.00 .97 .91
1.02 .98 .94 .89
1.00 .96 .92 .88
.99 .94 .90 .86
.97 .92 .89 .85
.95 .90 .87 .84
.94 .89 .86 .83
50 30 20
1.11 1.11 1.11
1.07 1.06 1.05
1.04 1.02 1.00
1.01 .99 .97
.99 .96 .94
.96 .93 .91
.94 .91 .89
.93 .90 .87
.91 .88 .86
.90 .87 .85
.88 .85 .83
50 30 20
1.06 1.06 1.06
1.04 1.03 1.02
1.01 1.00 .98
.99 .97 .95
.97 .94 .93
.95 .92 .91
.93 .91 .89
.92 .89 .87
.90 .88 .86
.89 .86 .84
.88 .85 .83
50 30 20
1.02 1.02 1.02
1.00 1.00 .99
.99 .97 .96
.97 .95 .94
.95 .93 .92
.93 .91 .90
.92 .90 .88
.91 .88 .87
.89 .87 .85
.88 .86 .84
.87 .85 .83
0
1.00
.97
.95
.93
.91
.89
.87
.86
.85
.83
.82
Coefficients Of Utilization -
Zonal Cavity Method
Zonal Lumen Summary
Zone Lumens % Lamp % Luminaire
0-30
1,062.6
88%
88.1%
0-40
1,134.6
94%
94.1%
0-60
1,197.4 99.2%
99.3%
60-90
8.1
0.7%
0.7%
0-90
1,205.5 99.9%
100%
90-180
0
0%
0%
0-180 1,205.5 99.9%
100%
Total Efficiency: 99.9%
Zonal Lumen
Center Beam fc
Beam Width
4.0 ft
8.0 ft
12.0 ft
16.0 ft
20.0 ft
24.0 ft
269 fc
67 fc
30 fc
17 fc
11 fc
7 fc
1.5 ft
3.0 ft
4.4 ft
5.9 ft
7.4 ft
8.9 ft
1.5 ft
3.0 ft
4.5 ft
5.9 ft
7.4 ft
8.9 ft
�
�
Vert. Spread: 20.9º
�
�
Horiz. Spread: 21.0º
Illuminance at Distance
ColorBlast 12
22° beam angle
Candela Table
0
5
15
25
35
45
55
65
75
85
90
0 22.5 44 67.5 90
4300
3614
1217
376
166
90
51
28
12
0
0
4300
3626
1222
377
166
90
52
29
12
0
0
4300
3633
1222
377
166
90
52
29
12
0
0
4300
3634
1224
378
166
90
52
29
12
0
0
4300
3616
1218
376
166
90
51
28
12
0
0
Polar Candela Distribution
RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio
Effective Floor Cavity Reflectance: 20%
RCC %:
80
70
50
30
10
0
RW %:
RCR: 0
1
2
3
4
5
6
7
8
9
10
70 50 30
0
1.19 1.19 1.19 1.19
1.14 1.11 1.08 1.06
1.08 1.04 1.00 .96
1.03 .97 .93 .89
.99 .92 .87 .83
.95 .87 .82 .78
.91 .83 .77 .74
.87 .79 .74 .70
.84 .76 .71 .67
.81 .73 .68 .64
.79 .70 .65 .62
70 50 30
0
1.16 1.16 1.16 1.00
1.11 1.09 1.07 .94
1.06 1.02 .98 .88
1.01 .96 .92 .83
.97 .91 .86 .79
.93 .86 .81 .75
.89 .82 .77 .72
.86 .78 .73 .69
.83 .75 .70 .66
.80 .72 .67 .63
.78 .70 .65 .61
50 30 20
1.11 1.11 1.11
1.05 1.03 1.01
.99 .96 .93
.93 .90 .87
.89 .84 .81
.84 .80 .77
.81 .76 .73
.77 .73 .69
.74 .70 .66
.71 .67 .64
.69 .65 .62
50 30 20
1.06 1.06 1.06
1.01 1.00 .98
.96 .93 .91
.91 .88 .85
.87 .83 .80
.83 .79 .76
.79 .75 .72
.76 .72 .69
.73 .69 .66
.71 .67 .64
.68 .64 .61
50 30 20
1.02 1.02 1.02
.98 .96 .95
.93 .91 .89
.89 .86 .84
.85 .82 .79
.81 .78 .75
.78 .75 .72
.75 .71 .69
.72 .69 .66
.70 .66 .63
.68 .64 .61
0
1.00
.94
.88
.82
.78
.74
.71
.67
.65
.62
.60
Coefficients Of Utilization -
Zonal Cavity Method
Zonal Lumen Summary
Zone
Lumens % Lamp % Luminaire
0-30
824.1
75.6%
75.7%
0-40
929.8
85.3%
85.4%
0-60
1,046.7
96%
96.1%
60-90
42.5
3.9%
3.9%
0-90
1,089.2
99.9%
100%
90-180
0
0%
0%
0-180
1,089.2
99.9%
100%
Total Efficiency: 99.9%
Zonal Lumen
Photometrics
Photometric data is based on test results from an independent NIST traceable testing
lab. IES data is available at www.colorkinetics.com/support/ies.
For lux multiply fc by 10.7
165 ft (50.3 m)
1 fc maximum distance
65.5 ft (19.9 m)
1 fc maximum distance
Cd: 0
4,557
9,114
13,672
18,229
22,786
27,343
VA: 0º
10º 20º
30º
40º
90º
80º
70º
60º
50º
�
- 0º H
�
- 90º H
Cd: 0
717
1,435
2,152
2,869
3,587
4,304
VA: 0º
10º 20º
30º
40º
90º
80º
70º
60º
50º
�
- 0º H
�
- 90º H
LED
Lumens Efficacy
RGB
1207
16.9
LED
Lumens Efficacy
RGB
1090
15.3