5/9
15,3
61
8
5
8
13
Aisle orientation for High Rack Optic (HRO)
162
17,7
Mount the protection cap
Protection cap must be tightened
with
proper
torque to avoid loosing
IP protection
!
3
!
ATTENTION
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC
SENSITIVE
DEVICES
I mains (A)
I nom.
Time (us)
Tref
max/2
I max
Inrush current
LED130S,
LED250S
LED350S
Electrical characteristics
Imax (A)
5,1
Tref (µs)
2300
MCB
No. of driver max.
B-10 A
8
B-16 A
12
C-10 A
12
C-16 A
20
The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE regulations or the national requirements.
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person
During the installation or maintaining the luminaire please use gloves to avoid spots on the cover
To remove dirt spots use the following:
- Dust: use micro fiber cloths
- Fingerprints, etc. : use a cleaner for with antistatic properties.
LED170S
17
22
28
36
Tightening torque
1 Nm
The following versions of the luminaires should be positioned so that
prolonged staring into the luminaire at a distance closer than the indicated
value in the table is not expected!
!
Luminaire type
Distance (m)
LED130S/865 NB
6.5
LED130S/865 XNB
10.2
LED170S/840 NB
6
LED170S/840 XNB
8.9
LED170S/865 NB
7.8
LED170S/865 XNB
11.8
LED250S/865 NB
9.9
LED250S/865 XNB
14.4
LED350S/840 NB
8.4
LED350S/840 XNB
12.8
LED350S/865 NB
14.1
LED350S/865 XNB
16.5
Содержание BY480P
Страница 6: ...6 9 ...
Страница 7: ...4 6 7 9 ...
Страница 8: ...5 6 8 9 ...
Страница 9: ...6 6 9 9 ...