![Philips BVP518 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/philips/bvp518/bvp518_manual_310506011.webp)
WIRING CONNECTION BOX L< 50m
BVP518
BVP528
CABLE DIAMETER
RANGE
MAX VOLTAGE
SUPPORTED
RECOMMENDED CABLE TYPE
L<25m
7G1.5
Ø13-Ø18
1000 V
H07RN-F 450V/750 or
A11VV U-600/1000V
L<50m
7G2.5
Ø13-Ø18
1000 V
H07RN-F 450V/750 or
A11VV U-600/1000V
50m<L<200m
8G2.5
Ø13-Ø18
1000 V
H07RN-F 450V/750 or
A11VV U-600/1000V
CABLE NOT SUPPLIED BY
PHILIPS IN VERSION BV
(7G 1.5/ 7G 2.5 mm2 ca-
ble or 6G1,5 mm2 cable
only for BVP518)
25
4
GND
6 5 4 1 2 3
GND
6 5 4 1 2 3
UNLOSABLE SCREWS
WITH RETAIN WASHERS
1
2
3
1. Pull the gland outwards
2. Insert the cable
3. Press back to original 90deg position
with a click (HGB VERSION ONLY)
4. Apply torque
4
2.5
25
3.5
32
L
BV VERSION
HGB VERSION
6G cable can be used and nº3
in image will not be connected
11/24
STRIPPING LENGTH:
8-9 mm
8-9 mm
6 core cable (6G) can be used for BVP518